Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T05CM04424
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/11/2005 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :*OK TO PLACE CONCRETE SPECIAL INSPECTION IS REQUIRED FOR ALL POST TENSION SLABS IN CITY OF TUCSON. BUILDING OFFICIAL HAS BEEN NOTIFIED. IN THE FUTURE, BEFORE C.O.T SHOWS UP: HAVE ALL CHAIRING-INCLUDING UPSIDE DOWN CHAIRS AT FARMS IN PLACE. HAVE ALL SWEEPS AROUND PLUMBING BOXES AND PIPES PROPERLY SET UP PER PLANS. MAXIMUN EXPOSED CABLE AT LIVE ENDS TO BE 1" PER PLAN. LIVE ENDS OF CABLE OUTSIDE FORM TO BE FREE. DON'T BURY THEM OR HAVE THEM RUNNING UP SIDES OF TAILINGS |