Permit: T05CM03695
Permit Details
Status:
C of o
Type:
DUPLEX NEW
Address:
8695 E PLACITA DE LAS TARASCAS #01
Address NEW:
8695 E PLACITA DE LAS TARASCAS #01
Apply Date:
07/13/2005
Applicant:
N/A
Description:
DUPLEX:TD#16-36-37
Contractors:
- WESTCRAFT BUILDERS INC
Permit Reviews
Permit Number - T05CM03695
Permit Status: C of o
Permit Description: DUPLEX:TD#16-36-37
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/13/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/14/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM03695
Permit Status: C of o
Permit Description: DUPLEX:TD#16-36-37
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/13/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM03695
Permit Description: DUPLEX:TD#16-36-37
Total Completed Inspections - 30
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2005 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* |
| 07/25/2006 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* CANCELLED BY CONTRACTOR |
| 03/22/2007 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* WATER TEST WASTE & VENT UNDERGROUND THRU BUILDING & HCS OK 1. SHALL SEE PIPE WRAPS PRIOR CONCRETE |
| 04/06/2007 | ELECTRIC - UFER | RJIROUDE | Approved | IVRS - Inspection :* |
| 04/06/2007 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* |
| 04/06/2007 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* |
| 05/25/2007 | ELECTRIC - CABLE DROP | RJIROUDE | Approved | IVRS - Inspection :* |
| 05/29/2007 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 05/31/2007 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
| 05/31/2007 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
| 05/31/2007 | EXT METAL CLIPS/EXT SHEATHING | GDABBS | Approved | IVRS - Inspection :* |
| 06/13/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 06/13/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* 1) PROVIDE BLOCKING AROUND CEILING BOXES PRIOR TO SHEETROCK 2) OK FOR SHEETROCK 3) DO NOT CURVE OR BEND THE PLASTIC CONDENSATE DRAINS |
| 06/13/2007 | MECHANICAL - UNDERGROUND | JMILITEL | Approved | IVRS - Inspection :* |
| 06/19/2007 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/19/2007 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/19/2007 | ELECTRIC - UNDERGROUND | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/21/2007 | U VALUE FOR WINDOW | GDABBS | Approved | IVRS - Inspection :* |
| 06/27/2007 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | WATER TEST WASTE & VENT THRU ROOF OK WATER PIPING OK 1. SHALL SEE SHOWER PAN & WASHING AREA PAN INSTALL WITH TEST. CLOSET FLANGES TO BE INSPECTED AFTER FLOORING. |
| 06/27/2007 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
| 06/27/2007 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* |
| 07/17/2007 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 08/13/2007 | ELECTRIC - TEMPORARY SERVICE | RJIROUDE | Approved | IVRS - Inspection :* |
| 08/14/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR #1 & #2 PER R. JIROUDEK-2ND TIME SENT TO TEP |
| 08/29/2007 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |
| 09/21/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 09/24/2007 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 09/24/2007 | SITE - SEWER | WNORTH | Approved | IVRS - Inspection :* |
| 09/25/2007 | ELECTRIC - FINAL | WNORTH | Approved | |
| 09/25/2007 | BUILDING - FINAL | GDABBS | Approved |