Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address NEW:
6073 E FARMSTEAD DR
Apply Date:
07/08/2005
Applicant:
CANATSEY BUILDING AND DEVELOPMEN
Description:
SFR:TD#16-29-71 R1 - Truss
Contractors:
  • CANATSEY BUILDING AND DEVELOPMEN

Permit Reviews

Permit Number - T05CM03589
Permit Status: C of o
Permit Description: SFR:TD#16-29-71 R1 - Truss
Start Date Submittal Complete Date Status  
01/22/2007 REVISION - - 1ST 01/22/2007 COMPLETED Review Details
07/08/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 07/11/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM03589
Permit Status: C of o
Permit Description: SFR:TD#16-29-71 R1 - Truss
Total Outstanding Activity Conditions - 1
Date Name
07/08/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM03589
Permit Description: SFR:TD#16-29-71 R1 - Truss
Total Completed Inspections - 25
Date Description Inspector Results Comments
11/09/2006 STEM WALL/RETAINING WALL EDURAZO Approved IVRS - Inspection :*
11/17/2006 PLUMBING - SEWER HCS CONNECT JRIVA Approved
11/17/2006 PLUMBING - YARD WTR LINE/TEST JRIVA Approved IVRS - Inspection :*
11/17/2006 PLUMBING - ROUGH, SOIL JRIVA Approved IVRS - Inspection :*
11/27/2006 EXCAVATION/LAYOUT REBAR & ZON CTREVILL Approved IVRS - Inspection :*
11/27/2006 BUILDING PRE-SLAB CTREVILL Approved IVRS - Inspection :*
12/18/2006 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) TRUSSES MUST BEAR AT MID POINT ON 3 PT BEARING WALL ENTRY
2) NO CITY OF TUCSON APPROVED TRUSS DRAWINGS ON SITE
3) AV1GE NOT BEARING AT POINT 21
4) AV TRUSSES NOT BEARING AT DT 17
5) AV TRUSSES INSTALLED IN AV1 LOCATIONS. PROVIDE CITY APPROVED TRUSS ENGINEERS REPAIR
6) PROVIDE CITY APPROVED DETAIL FOR SHEARWALL CONNECTION TO TRUSS SYSTEM AT PATIO
7) SHEARWALL 2 REQUIRES EDGE NAILING AT 4" ON CENTER
8) HOLDOWN REQUIRE 16D NAILS NOT GUN NAILS
9) CLIP GABLE END TRUSSES
01/24/2007 ELECTRIC - TEMPORARY SERVICE CRUIZ Approved IVRS - Inspection :*
01/24/2007 ELECTRIC - CABLE DROP CRUIZ Approved IVRS - Inspection :*
01/24/2007 ROOF NAILING CRUIZ Approved IVRS - Inspection :*
01/25/2007 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER C. RUIZ
02/14/2007 ELECTRIC - INTERMEDIATE CRUIZ Approved
02/14/2007 U VALUE FOR WINDOW CRUIZ Approved
02/14/2007 ELECTRIC - UFER CRUIZ Approved IVRS - Inspection :*
02/14/2007 PLUMBING - GAS PRESSURE TEST CRUIZ Approved IVRS - Inspection :*
02/14/2007 STUCCO MESH CRUIZ Approved IVRS - Inspection :*
02/14/2007 PLUMBING - INTERMEDIATE CRUIZ Approved IVRS - Inspection :*
02/16/2007 MECHANICAL - INTERMEDIATE EDURAZO Approved IVRS - Inspection :*
02/16/2007 FRAMING EDURAZO Approved IVRS - Inspection :*
02/23/2007 SHEET ROCK NAILING CRUIZ Approved IVRS - Inspection :*
05/10/2007 MECHANICAL - FINAL CRUIZ Approved IVRS - Inspection :*
05/10/2007 PLUMBING - FINAL CRUIZ Approved IVRS - Inspection :*
05/15/2007 ELECTRIC - FINAL CRUIZ Approved IVRS - Inspection :*
05/15/2007 BUILDING - FINAL CRUIZ Approved IVRS - Inspection :*
05/30/2007 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW
C OF O_05-30-2007.TIF CERT OF OCC VIEW