Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM02625
Permit Details
Apply Date:
06/08/2005
Applicant:
K B HOME OF TUCSON *C
Description:
SFR TD#15-44-67
Contractors:
- K B HOME OF TUCSON *C
Permit Reviews
Permit Number - T05CM02625
Permit Status: Final
Permit Description: SFR TD#15-44-67
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/08/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 06/14/2005 | COMPLETED |
10/05/2005 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 10/06/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02625
Permit Status: Final
Permit Description: SFR TD#15-44-67
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/08/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM02625
Permit Description: SFR TD#15-44-67
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/21/2005 | PLUMBING - SEWER HCS CONNECT | HPEDROZA | Approved | IVRS - Inspection :* |
09/21/2005 | PLUMBING - YARD WTR LINE/TEST | HPEDROZA | Approved | IVRS - Inspection :* |
09/21/2005 | PLUMBING - ROUGH, SOIL | HPEDROZA | Approved | IVRS - Inspection :* |
10/07/2005 | ELECTRIC - UFER | EDURAZO | Approved | IVRS - Inspection :* |
10/07/2005 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection :* |
10/07/2005 | STEM WALL/RETAINING WALL | EDURAZO | Approved | IVRS - Inspection :* |
10/07/2005 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* |
11/03/2005 | ROOF NAILING | FGREER | Approved | |
11/03/2005 | EXT METAL CLIPS/EXT SHEATHING | FGREER | Approved | |
12/21/2005 | STUCCO MESH | HPEDROZA | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH SEAL ALL PENETRATIONS 2) PANCAKE BOX NOT GROUNDED EXTERIOR 3) CHECK CABLES AT GARAGE FOR TENSION 4) NO TEST ON DWV'S 5) NAIL PROTECT WATER LINES AT LAUNDRY 6) REPLACE SHEAR PANEL AT KITCHEN SHEAR WALL 7) HD HTT16 ON WRONG WALL AT LAUNDRY 8) NAIL PROTECT ELECTRIC WIRES AT SEPERATION WALL FROM LIVING TO DINING 9) FIREBLOCK MISSING AT ENTRY CLOSET 10) STRONG BACKS MISSING 11) NAIL PROTECT ABS UPSTAIRS BATH 12) SECURE ROMEX WITHIN 8" FROM BOX AT MASTER 13) NAIL PROTECT LOW VOLTAGE WIRE THROUGHOUT 14) SHIM HEADERS WHERE NEED 15) FIXTURE BOX IN HALL BATH NOT GROUNDED 16) VENT AT UPSTAIRS HALL BATH NOT GLUED 17) SEAL LATH FROM INSIDE 18) GAS TEST AT ZERO 19) STOPPED INSPECTION |
12/21/2005 | U VALUE FOR WINDOW | HPEDROZA | Approved | IVRS - Inspection :* |
12/21/2005 | PLUMBING - GAS PRESSURE TEST | HPEDROZA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/21/2005 | MECHANICAL - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/21/2005 | PLUMBING - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/21/2005 | ELECTRIC - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/21/2005 | FRAMING | HPEDROZA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
02/02/2006 | ELECTRIC - TEMPORARY SERVICE | HPEDROZA | Approved | IVRS - Inspection :* |
02/02/2006 | ELECTRIC - CABLE DROP | HPEDROZA | Approved | IVRS - Inspection :* |
02/03/2006 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
02/14/2006 | SHEET ROCK NAILING | HPEDROZA | Approved | IVRS - Inspection :* |
03/31/2006 | MECHANICAL - FINAL | CTREVILL | Approved | |
03/31/2006 | PLUMBING - FINAL | CTREVILL | Approved | |
03/31/2006 | ELECTRIC - FINAL | CTREVILL | Approved | |
03/31/2006 | BUILDING - FINAL | CTREVILL | Approved |