Inspection History Details
Inspection Status: Approved
Inspection History: STUCCO MESH
Permit Number - T05CM02625
Inspection Description - STUCCO MESH
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/11/2006 | STUCCO MESH | Approved | IVRS - Inspection :* | |
01/09/2006 | STUCCO MESH | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
12/21/2005 | STUCCO MESH | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH SEAL ALL PENETRATIONS 2) PANCAKE BOX NOT GROUNDED EXTERIOR 3) CHECK CABLES AT GARAGE FOR TENSION 4) NO TEST ON DWV'S 5) NAIL PROTECT WATER LINES AT LAUNDRY 6) REPLACE SHEAR PANEL AT KITCHEN SHEAR WALL 7) HD HTT16 ON WRONG WALL AT LAUNDRY 8) NAIL PROTECT ELECTRIC WIRES AT SEPERATION WALL FROM LIVING TO DINING 9) FIREBLOCK MISSING AT ENTRY CLOSET 10) STRONG BACKS MISSING 11) NAIL PROTECT ABS UPSTAIRS BATH 12) SECURE ROMEX WITHIN 8" FROM BOX AT MASTER 13) NAIL PROTECT LOW VOLTAGE WIRE THROUGHOUT 14) SHIM HEADERS WHERE NEED 15) FIXTURE BOX IN HALL BATH NOT GROUNDED 16) VENT AT UPSTAIRS HALL BATH NOT GLUED 17) SEAL LATH FROM INSIDE 18) GAS TEST AT ZERO 19) STOPPED INSPECTION |