Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM02625

Parcel: 118043140


Addresses:

1232 S FLAXSEED DR


Inspection Status: Approved

Inspection History: STUCCO MESH

Permit Number - T05CM02625

Inspection Description - STUCCO MESH

Inspection Status - Approved

Date Description Inspector Results Comments
01/11/2006 STUCCO MESH Approved IVRS - Inspection :*
01/09/2006 STUCCO MESH Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/21/2005 STUCCO MESH Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATH SEAL ALL PENETRATIONS
2) PANCAKE BOX NOT GROUNDED EXTERIOR
3) CHECK CABLES AT GARAGE FOR TENSION
4) NO TEST ON DWV'S
5) NAIL PROTECT WATER LINES AT LAUNDRY
6) REPLACE SHEAR PANEL AT KITCHEN SHEAR WALL
7) HD HTT16 ON WRONG WALL AT LAUNDRY
8) NAIL PROTECT ELECTRIC WIRES AT SEPERATION WALL FROM LIVING TO DINING
9) FIREBLOCK MISSING AT ENTRY CLOSET
10) STRONG BACKS MISSING
11) NAIL PROTECT ABS UPSTAIRS BATH
12) SECURE ROMEX WITHIN 8" FROM BOX AT MASTER
13) NAIL PROTECT LOW VOLTAGE WIRE THROUGHOUT
14) SHIM HEADERS WHERE NEED
15) FIXTURE BOX IN HALL BATH NOT GROUNDED
16) VENT AT UPSTAIRS HALL BATH NOT GLUED
17) SEAL LATH FROM INSIDE
18) GAS TEST AT ZERO
19) STOPPED INSPECTION