Permit: T05CM02577
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
2656 W BROADWAY BL 11
Address NEW:
2656 W BROADWAY BL 11
Apply Date:
06/06/2005
Applicant:
N/A
Description:
NEW APTS/REC ROOM
Contractors:
- MULTIFAMILY BUILDING SPECIALISTS INC
Permit Reviews
Permit Number - T05CM02577
Permit Status: C of o
Permit Description: NEW APTS/REC ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/06/2005 | PLANS OK TO SUBMIT - 3RD PARTY | 06/06/2005 | COMPLETED |
| 06/06/2005 | 3RD PARTY REVIEW-COMMERCIAL | 09/13/2005 | COMPLETED |
| 06/14/2011 | RESUBMITTAL | 07/06/2011 | COMPLETED |
| 07/06/2011 | RESUBMITTAL | 07/26/2011 | COMPLETED |
| 07/07/2010 | POST 3RD PARTY REVIEW | 06/14/2011 | COMPLETED |
| 09/13/2005 | POST 3RD PARTY REVIEW | 01/19/2006 | COMPLETED |
| 11/03/2011 | REVISION - - 1ST | 11/03/2011 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02577
Permit Status: C of o
Permit Description: NEW APTS/REC ROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/06/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM02577
Permit Description: NEW APTS/REC ROOM
Total Completed Inspections - 31
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2011 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 09/06/2011 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* |
| 09/20/2011 | FIRE - FINAL | CSCHULTZ | Approved | Fire Safety During Construction All combustible material shall be within 300 feet of a working hydrant. All approved water supply shall be completely installed and working before anymore construction can be done. You can finish the rec. center, bldg 1 & 2, NO more buildings until approved water supply is done and working. |
| 10/05/2011 | FIRE SPKLR - UG PIPING FLUSH | CSCHULTZ | Approved | Hydro test and flush passed |
| 10/05/2011 | FIRE SPKLR - UG, PIPING, HYDRO | CSCHULTZ | Approved | Hydro test and flush passed |
| 10/12/2011 | FIRE - HYDRANTS | CSCHULTZ | Approved | |
| 10/13/2011 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1) ABS AND PVC TO BE SUPPORTED AT EACH CHANGE OF DIVERTION OR ELEVATION AND AT THE END OF BRANCHES THEN NO MORE THAN 4' BETWEEN HANGERS. VERTICAL PIPING REQUIRES MID STORY GUIDES 2) PLASTIC PIPE MAY NOT BE TESTED WITH AIR 3) WATER PIPE 1 1/2" AND SMALLER TO BE PEX SEE 1541D-2 PART 2 SECTION Z04B. INSTALLERS TO BE CERTIFIED SEE 302.A 4) INSULATE PER SPEC BOOK |
| 10/13/2011 | PLUMBING - ROOF DRAINS | RMYERS | Approved | IVRS - Inspection :* |
| 10/21/2011 | FIRE SPKLR - OH PIPING & HYDRO | WMOTTO | Approved | |
| 10/27/2011 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* 1) NEED TO SEE PANEL MAKE UP AND CABLE TERM INTO PANELS |
| 10/27/2011 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 11/04/2011 | ROOF NAILING | MHENSON | Approved | IVRS - Inspection :* |
| 11/04/2011 | EXT METAL CLIPS/EXT SHEATHING | MHENSON | Approved | IVRS - Inspection :* |
| 11/04/2011 | BUILDING PRE-SLAB | MHENSON | Approved | IVRS - Inspection :* |
| 11/04/2011 | EXCAVATION/LAYOUT REBAR & ZON | MHENSON | Approved | IVRS - Inspection :* |
| 11/04/2011 | FRAMING | MHENSON | Approved | IVRS - Inspection :* |
| 11/04/2011 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 11/04/2011 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 11/14/2011 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/17/2011 | STUCCO MESH | MHENSON | Approved | IVRS - Inspection :* |
| 01/23/2012 | PLUMBING - YARD WTR LINE/TEST | DQUINN | Approved | IVRS - Inspection :* |
| 02/01/2012 | ELECTRIC - CABLE DROP | DQUINN | Approved | IVRS - Inspection :* |
| 02/10/2012 | PLUMBING - SEWER HCS CONNECT | DQUINN | Approved | IVRS - Inspection :* |
| 03/09/2012 | TEP CLEARANCE - PM | JWEATHER | Approved | ECO CLEARED FOR BLDG #11 PER D. QUINN |
| 03/13/2012 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR BLDG 11-(CLUB HOUSE) NO UNITS |
| 03/19/2012 | PLUMBING - GAS PRESSURE TEST | DQUINN | Approved | IVRS - Inspection :* |
| 04/05/2012 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 04/05/2012 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 04/10/2012 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 04/10/2012 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 04/27/2012 | FIRE SPKLR - FINAL | WMOTTO | Approved |