Permit: T05CM02577

Parcel: 11611003H

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/05/2012 PLUMBING - INTERMEDIATE Approved
10/13/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) ABS AND PVC TO BE SUPPORTED AT EACH CHANGE OF DIVERTION OR ELEVATION AND AT THE END OF BRANCHES THEN NO MORE THAN 4' BETWEEN HANGERS. VERTICAL PIPING REQUIRES MID STORY GUIDES
2) PLASTIC PIPE MAY NOT BE TESTED WITH AIR
3) WATER PIPE 1 1/2" AND SMALLER TO BE PEX SEE 1541D-2 PART 2 SECTION Z04B. INSTALLERS TO BE CERTIFIED SEE 302.A
4) INSULATE PER SPEC BOOK