Permit: T05CM02351
Permit Details
Status:
Final
Type:
COMMERCIAL ALTERATION
Address:
915 N VENICE AV #A
Address NEW:
915 N VENICE AV #A
Apply Date:
05/24/2005
Applicant:
BRIGHT, RICK LANE
Description:
REMODEL:CONDO'S INTERIOR ; 4 - 2 BEDROOM UNITS, FURR-OUT AND SMOKE DETECTORS
Architects:
- BRIGHT, RICK LANE
Contractors:
- INFILL CONSTRUCTION L L C
Permit Reviews
Permit Number - T05CM02351
Permit Status: Final
Permit Description: REMODEL:CONDO'S INTERIOR ;
4 - 2 BEDROOM UNITS, FURR-OUT AND SMOKE DETECTORS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/24/2005 | COMMERCIAL TI | 08/26/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02351
Permit Status: Final
Permit Description: REMODEL:CONDO'S INTERIOR ;
4 - 2 BEDROOM UNITS, FURR-OUT AND SMOKE DETECTORS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/24/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM02351
Permit Description: REMODEL:CONDO'S INTERIOR ;
4 - 2 BEDROOM UNITS, FURR-OUT AND SMOKE DETECTORS
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/18/2005 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :*DWV WATER TEST IS OK OVERHEAD WATER DISTRIBUTION IS OK. AIR PRESSURE TEST IS OK |
| 10/18/2005 | PLUMBING - PROGRESS | TRINIVJR | Approved | IVRS - Inspection :* |
| 10/18/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection :* |
| 10/18/2005 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :* |
| 10/18/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :* |
| 10/19/2005 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 10/19/2005 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 10/20/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 10/20/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
| 10/21/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :*OK FOR SHEET ROCK |
| 11/03/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 12/30/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :*UNIT A RAISE VENT CONNECTORS AS HIGH AS POSSIBLE DISCONNECTS ON ROOF OVERFUSED. 30 AMP IS MAX. FINISH VENT PIPING ON ROOF. |
| 12/30/2005 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1. BOXES MORE THAN 1/4" FROM BOX TO SURFACE NEED AN APPROVED EXTENDER RING. ALSO FLUSH AT COMBUSTIBLES 2. FIXTURES TO BE GROUNDED ALSO HARDWARE AND FANS 3. PLEASE CLEAN OUT EXCESS DIRT & DEBRIS FROM PANEL 4. SECURE BOXES IN WALL 5. FULLY INSTALL CONDUCTORS UNDER TERMINAL SCREWS AT ROOF: DEVICES 6. PROPERLY SECURE BOX AND USE AN APPROVED FITTING CHASE NIPPLE OR CUT UP CONNECTORS NOT APPROVED. |
| 12/30/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* 1) PLUMBING FINAL IS OK 2) OK FOR C OF O |
| 01/03/2006 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | |
| 01/06/2006 | BUILDING - FINAL | JCAGLE | Approved | IVRS - Inspection :* |
| 07/10/2006 | PERMIT FINALED | LJACKSON | Approved |