Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :*OK FINAL | |
| 01/04/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. GROUND FIXTURES AND HARDWARE PER MANUFACTURERS INSTRUCTIONS 2. TIGHTEN LOOSE LOCK NUT AT A/C DISCONNECT 3. OPEN UP 2 CEILING FIXTURES PER UNIT AND 1 FAN CANOPY IF PRESENT 4. COMPLETE PREVIOUS ITEM 2, 4, 5 |
|
| 01/03/2006 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :*FINISH PREVIOUS ITEMS | |
| 12/30/2005 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. BOXES MORE THAN 1/4" FROM BOX TO SURFACE NEED AN APPROVED EXTENDER RING. ALSO FLUSH AT COMBUSTIBLES 2. FIXTURES TO BE GROUNDED ALSO HARDWARE AND FANS 3. PLEASE CLEAN OUT EXCESS DIRT & DEBRIS FROM PANEL 4. SECURE BOXES IN WALL 5. FULLY INSTALL CONDUCTORS UNDER TERMINAL SCREWS AT ROOF: DEVICES 6. PROPERLY SECURE BOX AND USE AN APPROVED FITTING CHASE NIPPLE OR CUT UP CONNECTORS NOT APPROVED. |