Permit: T05CM02347
Permit Details
Status:
Expired
Type:
COMMERCIAL ALTERATION
Address:
914 N DESERT AV #A
Address NEW:
914 N DESERT AV #A
Apply Date:
05/24/2005
Applicant:
N/A
Description:
REMODEL:CONDO'S INTERIOR
Architects:
- BRIGHT, RICK LANE
Contractors:
- INFILL CONSTRUCTION L L C
Permit Reviews
Permit Number - T05CM02347
Permit Status: Expired
Permit Description: REMODEL:CONDO'S INTERIOR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/24/2005 | COMMERCIAL TI | 09/27/2005 | COMPLETED |
| 11/17/2005 | RESUBMITTAL | 11/30/2005 | COMPLETED |
| 11/30/2005 | RESUBMITTAL | 11/30/2005 | COMPLETED |
| 11/30/2005 | RESUBMITTAL | 12/02/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02347
Permit Status: Expired
Permit Description: REMODEL:CONDO'S INTERIOR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/24/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM02347
Permite Description: REMODEL:CONDO'S INTERIOR
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| FIRE - FINAL | N/A | Not Inspected |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM02347
Permit Description: REMODEL:CONDO'S INTERIOR
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :*OK FOR SHEET ROCK |
| 12/06/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection :* GAS PRESSURE TEST IS OK |
| 12/06/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection : See detailed listing on site.| 999* DWV WATER TEST IS OK WATER DISTRIBUTION IS OK OK FOR DRY WALL GAS PRESSURE IS DOWN |
| 12/06/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :* |
| 12/06/2005 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :* |
| 12/09/2005 | FRAMING | LHANLY | Approved | IVRS - Inspection :* 1) MUST HAVE ADDRESS POSTED |
| 12/16/2005 | SHEET ROCK NAILING | JCAGLE | Approved | IVRS - Inspection :*APPROVED |
| 01/30/2006 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* OK FINAL 1. MECHANICAL INSPECTOR TO CHECK DUCTING CLEARANCES AT PANEL |
| 01/30/2006 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
| 01/30/2006 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 02/06/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 02/07/2006 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 02/07/2006 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection :* |
| 02/07/2006 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
| 02/07/2006 | BUILDING - FINAL | JCAGLE | Approved | IVRS - Inspection :* |
| 02/07/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :*PLUMBER TO FILL ALL WATER HEATERS, BLEED OF ALL THE AIR, CLEAN THE AERATORS, AND TEST THE FIXTURES BY FILLING THEM WITH WATER-THEN RELEASING IT AND OBSERVE IF THERE ARE ANY LEAKS. |
| 02/07/2006 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |