Permit: T05CM02256
Permit Details
Apply Date:
05/18/2005
Applicant:
CARAVAN INC
Description:
DUPLEX TD#15-69-88
Contractors:
- LINEAR CONSTRUCTION INC
Permit Reviews
Permit Number - T05CM02256
Permit Status: Final
Permit Description: DUPLEX TD#15-69-88
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/18/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 05/18/2005 | COMPLETED |
| 06/08/2006 | REVISION - - 1ST | 06/08/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02256
Permit Status: Final
Permit Description: DUPLEX TD#15-69-88
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/18/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM02256
Permit Description: DUPLEX TD#15-69-88
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/14/2006 | ELECTRIC - TEMPORARY SERVICE | CCLEMENS | Approved | IVRS - Inspection : 1. SERVICE DISCONNECT CANNOT BE USED AS A TEMPORARY SERVICE. NEED A PANEL BOARD ALSO TO HANDLE BRANCH CKTS, ALSO, EXPOSE GROUND RODS. |
| 06/21/2006 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* 1. ABS DWV UNDERSLAB OK TO COVER WATER TEST ONE RISER TO TEN FEET. 2. SEWER/HCS OK OK TO COVER |
| 06/21/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 06/28/2006 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/28/2006 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/05/2006 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection :* *NOTE: TEMP SERVICE NEEDS HOLDDOWN KIT FOR BACK FED MAIN OK USE MAIN LUG ONLY. ALSO, INSTALL ADDRESS ON SERVICE, EXPOSE GROUND RODS. |
| 07/21/2006 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/21/2006 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2006 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2006 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2006 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/06/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 09/07/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* OK ELECTRICAL COVER |
| 09/14/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS TUBS OK CLOSET FLANGES OK |
| 09/15/2006 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/19/2006 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. INSTALL ADDRESS AND UNIT NUMBERS ON SERVICE 2. IDENTIFY SERVICE DISCONNECTS. 3. TERMINATE FEEDERS AND GROUNDING CONDUCTORS. 4. BOND ANY METAL PIPING TO SERVICE -- GAS & WATER 5. INSTALL SERVICE LATERAL LUGS. 6. SEAL UNUSED OPENINGS. 7. BOND SERVICE RISER 8. STRAP SERVICE RISER 9. SERVICE RACEWAY OUT OF SERVICE INTO GROUND TO BE 18" DEEP 10. UNITS TO BE TRIMMED OUT BEFORE POWER APPROVAL. 11. SECURE SERVICE TO STRUCTURE - GET INTO SOME STUDS AND USE BIGGER SCREWS. |
| 10/19/2006 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
| 12/13/2006 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* 1) SERVICE INSPECTION ONLY 2) IDENTIFY SERVICE DISCONNECTS-NEC 230.70(B) |
| 12/14/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR BOTH UNITS PER C. CLEMENS |
| 12/29/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1) PLUMBING FINAL OK 2) OK FOR C OF O S.T.O.I. |
| 12/29/2006 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 02/13/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 02/15/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/16/2007 | PERMIT FINALED | BFLORES | Approved |