Permit Details

Status:
Final
Type:
DUPLEX NEW
Address:
3042 N BALBOA AV
Address NEW:
3042 N BALBOA AV
Apply Date:
05/18/2005
Applicant:
CARAVAN INC
Description:
DUPLEX TD#15-69-88
Contractors:
  • LINEAR CONSTRUCTION INC

Permit Reviews

Permit Number - T05CM02256
Permit Status: Final
Permit Description: DUPLEX TD#15-69-88
Start Date Submittal Complete Date Status  
05/18/2005 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 05/18/2005 COMPLETED Review Details
06/08/2006 REVISION - - 1ST 06/08/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM02256
Permit Status: Final
Permit Description: DUPLEX TD#15-69-88
Total Outstanding Activity Conditions - 1
Date Name
05/18/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM02256
Permit Description: DUPLEX TD#15-69-88
Total Completed Inspections - 24
Date Description Inspector Results Comments
06/14/2006 ELECTRIC - TEMPORARY SERVICE CCLEMENS Approved IVRS - Inspection :
1. SERVICE DISCONNECT CANNOT BE USED AS A TEMPORARY SERVICE. NEED A PANEL BOARD ALSO TO HANDLE BRANCH CKTS, ALSO, EXPOSE GROUND RODS.
06/21/2006 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
1. ABS DWV UNDERSLAB OK TO COVER
WATER TEST ONE RISER TO TEN FEET.
2. SEWER/HCS OK
OK TO COVER
06/21/2006 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
06/28/2006 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
06/28/2006 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
07/05/2006 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :*
*NOTE: TEMP SERVICE NEEDS HOLDDOWN KIT FOR BACK FED MAIN OK USE MAIN LUG ONLY. ALSO, INSTALL ADDRESS ON SERVICE, EXPOSE GROUND RODS.
07/21/2006 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
07/21/2006 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
08/30/2006 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
08/30/2006 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
08/30/2006 FRAMING AQUIROZ Approved IVRS - Inspection :*
09/06/2006 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
09/07/2006 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
OK ELECTRICAL COVER
09/14/2006 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
OK TO COVER ALL AREAS
TUBS OK
CLOSET FLANGES OK
09/15/2006 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
10/19/2006 ELECTRIC - UNDERGROUND CCLEMENS Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. INSTALL ADDRESS AND UNIT NUMBERS ON SERVICE
2. IDENTIFY SERVICE DISCONNECTS.
3. TERMINATE FEEDERS AND GROUNDING CONDUCTORS.
4. BOND ANY METAL PIPING TO SERVICE -- GAS & WATER
5. INSTALL SERVICE LATERAL LUGS.
6. SEAL UNUSED OPENINGS.
7. BOND SERVICE RISER
8. STRAP SERVICE RISER
9. SERVICE RACEWAY OUT OF SERVICE INTO GROUND TO
BE 18" DEEP
10. UNITS TO BE TRIMMED OUT BEFORE POWER APPROVAL.
11. SECURE SERVICE TO STRUCTURE - GET INTO SOME STUDS AND USE BIGGER SCREWS.
10/19/2006 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
12/13/2006 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :*
1) SERVICE INSPECTION ONLY
2) IDENTIFY SERVICE DISCONNECTS-NEC 230.70(B)
12/14/2006 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR BOTH UNITS PER C. CLEMENS
12/29/2006 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
1) PLUMBING FINAL OK
2) OK FOR C OF O S.T.O.I.
12/29/2006 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
02/13/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
02/15/2007 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
02/16/2007 PERMIT FINALED BFLORES Approved