Permit: T05CM02255
Permit Details
Apply Date:
05/18/2005
Applicant:
CARAVAN INC
Description:
DUPLEX TD#15-69-88
Contractors:
- LINEAR CONSTRUCTION INC
Permit Reviews
Permit Number - T05CM02255
Permit Status: Final
Permit Description: DUPLEX TD#15-69-88
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/08/2007 | REVISION - - 2ND | 01/08/2007 | ACTIVE |
| 05/18/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 05/18/2005 | COMPLETED |
| 06/08/2006 | REVISION - - 1ST | 06/08/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02255
Permit Status: Final
Permit Description: DUPLEX TD#15-69-88
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/18/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM02255
Permit Description: DUPLEX TD#15-69-88
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2006 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* 1. ABS DWV UNDERGROUND OK WATER TEST ONE RISER TO TEN FEET OK 2. SEWER/HCS CONNECTION OK OK TO COVER |
| 06/21/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 06/28/2006 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* SOUTH SIDE PROPERTY LINE DOES NOT MATCH PLEASE REVISE POUR AT YOUR OWN RISK. |
| 06/28/2006 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/05/2006 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection :* |
| 07/24/2006 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/24/2006 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2006 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2006 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/06/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 09/07/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* OK ELECTRICAL COVER |
| 09/14/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS TUBS OK CLOSET FLANGES OK |
| 09/18/2006 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* EXCLUDES RESTROOM PARTY WALL AT #1 |
| 10/19/2006 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* SEE REPORT FOR T05CM02256 |
| 10/19/2006 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/13/2006 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* 1) INSPECTION FOR SERVICE ONLY 2) IDENTIFY SERVICE DISCONNECTS-NEC 230.70(B) |
| 12/14/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR BOTH UNITS PER C. CLEMENS |
| 12/29/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1) CLEANOUTS IN DRIVEWAY TO BE MADE TRAFFIC RATED 2) PLUMBING INSIDE OK |
| 12/29/2006 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 02/13/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 02/14/2007 | ELECTRIC - TEMPORARY SERVICE | CCLEMENS | Approved | IVRS - Inspection :* |
| 02/15/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/15/2007 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/16/2007 | PERMIT FINALED | BFLORES | Approved |