Permit: T05CM01842
Permit Details
Apply Date:
04/26/2005
Applicant:
ROSE WENDELLE A
Description:
RECONNECT:ELECTRIC & GAS GUEST HOUSE
Outstanding Activity Conditions
Permit Number - T05CM01842
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC & GAS GUEST HOUSE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/26/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM01842
Permite Description: RECONNECT:ELECTRIC & GAS GUEST HOUSE
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2005 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MINIMUM 10 PSI TEST SHALL HOLD FOR 15 MINUTES WITH NO PRESSURE DROP |
08/25/2005 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE RIDGID DRAIN PIPE TERMINATE 6" FROM FINISH GRADE FOR WATER HEATER TEMPERATURE AND PRESSURE RELIEF DRAIN 3) PROVIDE 5' MINIMUM VENT PIPE WITH APPROVED VENT CAP FOR WATER HEATER 4) PROVIDE BONDING OF BLDG GAS 5) PROVIDE TEST GAUGE IN 1/10 POUND INCREMENTS |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM01842
Permit Description: RECONNECT:ELECTRIC & GAS GUEST HOUSE
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/11/2005 | ELECTRIC - RECONNECT | DSANTACR | Approved | |
10/11/2005 | ELECTRIC - FINAL | DSANTACR | Approved | |
10/11/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | PER DAN SANTA CRUZ OK TO RECON |