Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
Permit Number - T05CM01842
Inspection Description - PLUMBING - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE RIDGID DRAIN PIPE TERMINATE 6" FROM FINISH GRADE FOR WATER HEATER TEMPERATURE AND PRESSURE RELIEF DRAIN 3) PROVIDE 5' MINIMUM VENT PIPE WITH APPROVED VENT CAP FOR WATER HEATER 4) PROVIDE BONDING OF BLDG GAS 5) PROVIDE TEST GAUGE IN 1/10 POUND INCREMENTS |
|
04/27/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* NOT READY FOR INSPECTION |