02/28/2005 PLANS OK TO SUBMIT - 3RD PARTY 03/03/2005 COMPLETED Review Details
03/03/2005 3RD PARTY REVIEW-COMMERCIAL 03/24/2005 COMPLETED Review Details
03/24/2005 POST 3RD PARTY REVIEW 04/12/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM00882
Permit Status: Final
Permit Description: NEW:RETAIL SHELL BLDG
Total Outstanding Activity Conditions - 1
Date Name
02/28/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM00882
Permit Description: NEW:RETAIL SHELL BLDG
Total Completed Inspections - 39
Date Description Inspector Results Comments
07/21/2005 ELECTRIC - UFER RSUBA Approved IVRS - Inspection :*
08/02/2005 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
1) 2" FROM METER THRU BACKFLOW DEVICE UP AT BLDG OK
08/11/2005 STEM WALL/RETAINING WALL LHANLY Approved IVRS - Inspection :*
08/11/2005 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
09/19/2005 REINFORCED MASONRY PRE-GROUT LHANLY Approved IVRS - Inspection :*
10/17/2005 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection :*
10/20/2005 ELECTRIC - UNDERGROUND RSUBA Approved IVRS - Inspection :*OK PAR FEEDER 3-4"
10/21/2005 ROOF NAILING LHANLY Approved IVRS - Inspection :*
11/07/2005 ELECTRIC - INTERMEDIATE RSUBA Approved IVRS - Inspection :*NORTHWALL OK TO COVER
OK TO ONE SIDE SOUTHWALL
11/10/2005 ELECTRIC - ABOVE CEILING RSUBA Approved IVRS - Inspection :*SOFFIT LIGHTS ( SHELL)
11/10/2005 FRAMING LHANLY Approved IVRS - Inspection :*
11/10/2005 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection :*
11/15/2005 PLUMBING - SEWER HCS CONNECT BBENEDON Approved IVRS - Inspection :*HCS CONNECTION OK
5 PSI PRESSURE TEST ON BACKWATER VALVE OK
12/16/2005 PLUMBING - ROOF DRAINS RRICH Approved IVRS - Inspection :*
1) WATER TEST (5) SETS 4" RD + 4" ORD WATER TEST OK PENDING CITY REVISED APPROVED PLAN OF TERMINATION OF RAIN DRAINS AND OVERFLOW RAIN DRAIN
12/16/2005 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
12/16/2005 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection :*
12/16/2005 STUCCO MESH LHANLY Approved IVRS - Inspection :*
12/16/2005 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection :*
12/16/2005 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
01/27/2006 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
01/27/2006 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
01/27/2006 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection :*
01/27/2006 ELECTRIC - OUTDOOR LIGHTING RSUBA Approved IVRS - Inspection :*
01/30/2006 TEP CLEARANCE - AM JKOZUCH Approved HP-5
02/08/2006 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*PERMANENTLY IDENTIFY SUITE NUMBERS & DATA PLATES ON A/C UNITS/ RECALL FOR INSPECTION
02/08/2006 FIRE - FINAL LTHOMAS Approved
02/08/2006 FIRE SPKLR - FINAL LTHOMAS Approved
02/08/2006 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
02/08/2006 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
02/08/2006 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
02/08/2006 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
02/09/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
02/09/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
06/19/2006 ENGINEERING - FINAL NKALAHAR Approved TEMP C OF O ONLY UNTIL ALL SITE WORK COMPLETE
T03BU03084 IS ASSOCIATED GRADING PERMIT NOT YET COMPLETE FOR THE SITE
CALLED AND SPOKE TO CHARLIE AT 250-5124

DRAINAGEWAY STILL HOLDING WATER
RIP RAP NOT COMPLETE
SITE WORK NOT DONE
06/19/2006 RIGHT OF WAY - FINAL NBRIGGS Approved PER EMAIL
08/24/2006 BUILDING - FINAL LHANLY Approved
08/24/2006 PLUMBING - FINAL LHANLY Approved
08/24/2006 OUTDOOR LIGHTING FINAL RSUBA Approved
06/02/2007 PERMIT FINALED BGRANT Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW