Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
5125 S ZENITH WY
Apply Date:
02/18/2005
Applicant:
SHIPLEY LESLIE R & DORIS N JT/RS
Description:
NEW:SFR

Permit Reviews

Permit Number - T05CM00740
Permit Status: C of o
Permit Description: NEW:SFR
Start Date Submittal Complete Date Status  
02/18/2005 PLANS OK TO SUBMIT - RES 02/18/2005 COMPLETED Review Details
02/18/2005 RESIDENTIAL BLDG/WWM 03/18/2005 COMPLETED Review Details
05/12/2005 RESUBMITTAL 05/25/2005 COMPLETED Review Details
05/25/2005 RESUBMITTAL 06/15/2005 COMPLETED Review Details
06/20/2005 RESUBMITTAL 06/20/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM00740
Permit Status: C of o
Permit Description: NEW:SFR
Total Outstanding Activity Conditions - 1
Date Name
02/18/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM00740
Permit Description: NEW:SFR
Total Completed Inspections - 27
Date Description Inspector Results Comments
09/21/2005 STEM WALL/RETAINING WALL RFREIDIN Approved IVRS - Inspection :*
10/01/2005 PLUMBING - ROUGH, SOIL EDURAZO Approved IVRS - Inspection :*
10/27/2005 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection :*
1) FLR. RECPTACLES DELETED
2) WRAP ALL AB'S PIPE IN CONTACT WITH CONCRETE
2) MAKE SURE YOU HAVE A 20" LAP (VERTICAL) BARS COMING OUT OF STEM WALL
3) 40 BAR DIAMETERS PAGE S.5
03/28/2006 REINFORCED MASONRY PRE-GROUT RFREIDIN Approved IVRS - Inspection :*
1) WAS TOPPED OUT
2) HAVE ENGINEERED OK ON MISSING 5/8 DIAMETER SILL BOLTS AT 24" ON CENTER IN LIEU OF 3/4 DIAMETER AT 30" ON CENTER
06/20/2006 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :*
1) OK FOR GARAGE SHEAR
2) NEED TRUSS DRAWINGS
08/09/2006 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
1) NEED APPROVED TRUSS DRAWINGS, DON'T LOAD
2) REPLACE POST AT PORCH AT FRONT PORCH
12/18/2006 SITE - SEWER WNORTH Approved IVRS - Inspection :*
12/18/2006 PLUMBING - SEWER HCS CONNECT WNORTH Approved IVRS - Inspection :*
12/18/2006 PLUMBING - YARD WTR LINE/TEST WNORTH Approved IVRS - Inspection :*
12/18/2006 ELECTRIC - UNDERGROUND WNORTH Approved IVRS - Inspection :*
12/19/2006 ELECTRIC - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
EXHAUST FAN CIRCUIT IN KITCHEN
SECURE 4 GANG BOXES BOTH SIDES.
MOVE ATTIC BOX FROM BEHIND DUCT
ADD DISCONNECT TO FURNACE
NEED POWER TO FILTER SYSTEM
12/19/2006 FRAMING WNORTH Approved IVRS - Inspection :*
ATTIC ACCESS MUST HAVE
22X30 CLEAR TO PLATFORM
12/19/2006 STUCCO MESH WNORTH Approved IVRS - Inspection :*
12/19/2006 MECHANICAL - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
12/19/2006 PLUMBING - INTERMEDIATE WNORTH Approved IVRS - Inspection :*
02/08/2007 ELECTRIC - UFER WNORTH Approved IVRS - Inspection :*
1) GROUND RODS
02/08/2007 U VALUE FOR WINDOW WNORTH Approved IVRS - Inspection :*
02/20/2007 SHEET ROCK NAILING WNORTH Approved IVRS - Inspection :*
1) CONNECT GROUND WIRE IN PANEL
2) INSTALL TEMP POWER RECEPTACLE
03/20/2007 ELECTRIC - TEMPORARY SERVICE WNORTH Approved
03/20/2007 ELECTRIC - CABLE DROP WNORTH Approved IVRS - Inspection :*
03/21/2007 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER W. NORTH
08/22/2007 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved
08/22/2007 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
08/22/2007 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
08/22/2007 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
08/22/2007 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*
08/23/2007 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW