Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T05CM00740
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/01/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
09/23/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE LAST INSPECTION |
|
09/21/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) IN VENT USE SAN T'S NOT COMBOS 2) TRAP ARMS TO REDUCE ONE PIPE SMALLER AS THEY STACK, FOR WET VENTING 3) TRAP ARMS ARE MIITED TO WET VENTING NO DRAINS REMOVE TUB FROM STACK RUN DRAIN SEPERATE 4) DBL FIXTURE FITTING NOT ALLOWED LAYING FLAT USE A DBL WYE 3 1/8 BEND OR TWO SEPERATE BRANCH LIMES 5) KIT ONLY REQUIRES ONE VERT PIPE |