Permit: T05CM00740

Parcel: 141013760


Addresses:

5125 S ZENITH WY


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T05CM00740

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
10/01/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/23/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE LAST INSPECTION
09/21/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) IN VENT USE SAN T'S NOT COMBOS
2) TRAP ARMS TO REDUCE ONE PIPE SMALLER AS THEY STACK, FOR WET VENTING
3) TRAP ARMS ARE MIITED TO WET VENTING NO DRAINS REMOVE TUB FROM STACK RUN DRAIN SEPERATE
4) DBL FIXTURE FITTING NOT ALLOWED LAYING FLAT USE A DBL WYE 3 1/8 BEND OR TWO SEPERATE BRANCH LIMES
5) KIT ONLY REQUIRES ONE VERT PIPE