Permit: T05CM00571
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
7290 E TANQUE VERDE RD
Address NEW:
7290 E TANQUE VERDE RD
Apply Date:
02/09/2005
Applicant:
RICHARD BURTON
Description:
NEW:SNACK BAR
Permit Reviews
Permit Number - T05CM00571
Permit Status: C of o
Permit Description: NEW:SNACK BAR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/09/2005 | PLANS OK TO SUBMIT - COMM | 04/19/2005 | COMPLETED |
| 04/19/2005 | 3RD PARTY REVIEW-COMMERCIAL | 06/24/2005 | COMPLETED |
| 06/24/2005 | POST 3RD PARTY REVIEW | 07/01/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM00571
Permit Status: C of o
Permit Description: NEW:SNACK BAR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/09/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM00571
Permit Description: NEW:SNACK BAR
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2005 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
| 09/13/2005 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection :* |
| 09/13/2005 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* |
| 09/27/2005 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection :* |
| 10/19/2005 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* ON FINAL INSULATE ALL DUCT WORK AS PER PLANS. PROVIDE A DRAIN ON EVAP COOLER TO AN APPROVED LOCATION. |
| 10/19/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 10/20/2005 | FRAMING | LHANLY | Approved | IVRS - Inspection :* |
| 10/26/2005 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :*PREVENT DIEELECTRIC CONTACT PROTECT M/C CABLE AT STUDS NOTE DERATING AS PER 310.15 NOTE 9H OF SPECS OK WALLS |
| 10/26/2005 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 10/28/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :*DWV WATE TEST IS OK OVERHEAD WATER DISTRIBUTION IS OK OK FOR DRY WALL |
| 11/02/2005 | ROOF NAILING | JCAGLE | Approved | IVRS - Inspection :* |
| 11/14/2005 | SHEET ROCK NAILING | JCAGLE | Approved | IVRS - Inspection :* 1) OK TO TAPE |
| 12/14/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :*OK FOR FINAL |
| 12/14/2005 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :*PLBG FINAL IS OK OK FOR C OF O . |
| 12/14/2005 | ELECTRIC - OUTDOOR LIGHTING | RHOLLAND | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTA HOT NOT LISTED AS A CORD & PLUG APPLIANCE 2. LABEL DISCONNECT & PANEL ON OUTSIDE COVER AND MAIN DISCONNECT AS PER NOTE 12 OF PLANS. 3. TIGHTEN LOOSE BUSHING & LUG 4. SPLIT BOLT ONLY LISTED FOR 2 CONDUCTORS - A RUN & A TAP 5. GROUNDING ELECTRODE TO BE CONNECTED AT GROUNDED CONNECTION ALSO AT 1ST DISCONNECTING MEANS. 6. WHERE IS GROUND RODS AND LETTER FROM ENGINEER FOR GROUNDING CHANGE? 7. REVISE PLANS FOR TRANSFORMER MOUNTING 8. MAIN BONDING JUMPER TO BE SIZED PER 250.66 9. BLUE WIRE NUT NOT LISTED FOR THAT MANY CONDUCTORS 10. VERIFY DERATING PER 310.15 - NOTE 7 DOES NOT ALLOW COMBINING OF HOME RUNS. 11. PLEASE VERIFY WEATHERPROOFING OF SPLICES 12. WHERE ARE OUTSIDE WALL LIGHTS. 13. PLEASE OPEN FRONT LIGHTS TO VERIFY AS PER PLANS. |
| 12/14/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* |
| 12/30/2005 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1) RECEIVED LETTER-FINISH PREVIOUS |
| 01/04/2006 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | PER ELEC FINAL |
| 01/05/2006 | BUILDING - FINAL | JCAGLE | Approved | IVRS - Inspection :* |
| 01/05/2006 | BUILDING - PROGRESS | JCAGLE | Approved | IVRS - Inspection :* |
| 01/09/2006 | FIRE - FINAL | LTHOMAS | Approved | |
| 01/27/2006 | PERMIT FINALED | LJACKSON | Approved | |
| 01/27/2006 | ENGINEERING - FINAL | EDUARTE | Approved | OK PER ERNIE DUARTE |
| 01/27/2006 | ENGINEERING - FINAL | JFEMLING | Approved | John B. will work with Parks to revise existing curb ramps. |
| 03/01/2006 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |