Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM00375
Permit Details
Apply Date:
01/27/2005
Applicant:
KAY CARRINGTON
Description:
ADDITION:DEFFERED WAREHOUSE
Permit Reviews
Permit Number - T05CM00375
Permit Status: C of o
Permit Description: ADDITION:DEFFERED WAREHOUSE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/27/2005 | PLANS OK TO SUBMIT - COMM | 01/27/2005 | COMPLETED |
01/27/2005 | PLANS OK TO SUBMIT - SITE | 03/10/2005 | COMPLETED |
01/27/2005 | 3RD PARTY REVIEW-COMMERCIAL | 02/25/2005 | COMPLETED |
02/25/2005 | POST 3RD PARTY REVIEW | 03/09/2005 | COMPLETED |
03/09/2005 | RESUBMITTAL | 04/14/2005 | COMPLETED |
03/10/2005 | SITE | 04/14/2005 | COMPLETED |
04/14/2005 | RESUBMITTAL - SITE | 04/26/2005 | COMPLETED |
04/14/2005 | RESUBMITTAL | 04/26/2005 | COMPLETED |
06/06/2005 | REVISION - SITE | 08/08/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM00375
Permit Status: C of o
Permit Description: ADDITION:DEFFERED WAREHOUSE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/27/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM00375
Permit Description: ADDITION:DEFFERED WAREHOUSE
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/28/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* APPROVED TRASH ENCLOSER |
04/28/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
07/18/2005 | OUTDOOR LIGHTING FINAL | DSANTACR | Approved | IVRS - Inspection :* |
07/18/2005 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | IVRS - Inspection :* |
07/22/2005 | ELECTRIC - PROGRESS | RSUBA | Approved | IVRS - Inspection :* |
07/22/2005 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | IVRS - Inspection :* |
07/22/2005 | ELECTRIC - UNDERGROUND | RSUBA | Approved | IVRS - Inspection :* |
07/27/2005 | BUILDING - PROGRESS | AMATHIES | Approved | IVRS - Inspection :* |
07/27/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
07/27/2005 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection :* |
07/27/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
07/27/2005 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
08/01/2005 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
08/01/2005 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection :* |
08/01/2005 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |
08/01/2005 | FIRE - FINAL | LLAKEY | Approved | |
08/01/2005 | ENGINEERING - FINAL | MAVERY | Approved | Contractor still needs to address punch-list for permit T05BU00687 |
08/01/2005 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
08/01/2005 | ELECTRIC - CONSTRUCTION POWER | DSANTACR | Approved | IVRS - Inspection :* |
08/01/2005 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* |
08/01/2005 | LANDSCAPE - FINAL | ACONNOR | Approved | |
08/07/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* 1) SUSPENDED SUPPLY EVAP. COOLER DUCT IN WAREHOUSE 2) PROGRESSING 3) ITEM 4035 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR C. WILLIAMS |
08/08/2005 | ELECTRIC - SERVICE UPGRADE | DSANTACR | Approved | |
08/08/2005 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
08/08/2005 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
08/08/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |