Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
719 W JACINTO ST
Address NEW:
719 W JACINTO ST
Apply Date:
01/04/2005
Applicant:
ROCHA HECTOR R & SOCORRO JT/RS
Description:
ADDITION:BEDROOM/BATH/LAUNDRY ROOM T04VL00206

Permit Reviews

Permit Number - T05CM00044
Permit Status: Expired
Permit Description: ADDITION:BEDROOM/BATH/LAUNDRY ROOM T04VL00206
Start Date Submittal Complete Date Status  
01/04/2005 RESIDENTIAL BLDG/ZONING/ENGINE/WWM 01/05/2005 COMPLETED Review Details
01/05/2005 RESIDENTIAL BLDG/WWM 04/15/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM00044
Permit Status: Expired
Permit Description: ADDITION:BEDROOM/BATH/LAUNDRY ROOM T04VL00206
Total Outstanding Activity Conditions - 1
Date Name
01/04/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05CM00044
Permite Description: ADDITION:BEDROOM/BATH/LAUNDRY ROOM T04VL00206
Total Outstanding Inspections - 16
Last Inspection Date Description Inspector Results Comments
EXT METAL CLIPS/EXT SHEATHING N/A Not Inspected
ROOF NAILING N/A Not Inspected
FRAMING N/A Not Inspected
STUCCO MESH N/A Not Inspected
U VALUE FOR WINDOW N/A Not Inspected
SHEET ROCK NAILING N/A Not Inspected
ELECTRIC - INTERMEDIATE N/A Not Inspected
ELECTRIC - SERVICE RELOCATION N/A Not Inspected
ELECTRIC - SERVICE UPGRADE N/A Not Inspected
PLUMBING - INTERMEDIATE N/A Not Inspected
MECHANICAL - INTERMEDIATE N/A Not Inspected
06/22/2006 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ANSWER AT DOOR-NO ACCESS
2) NO PLANS/PERMIT VISIBLE
3) WILL NEED VERIFICATION OF ALL PREVIOUS WORK BEING INSPECTED AT APPROVED
4) STOPPED INSPECTION-RECALL
06/22/2006 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/22/2006 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/22/2006 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/23/2006 BUILDING PRE-SLAB N/A Not ready for Inspection IVRS - Inspection :*

Completed Inspections

Permit Status: Expired
Permit Number: T05CM00044
Permit Description: ADDITION:BEDROOM/BATH/LAUNDRY ROOM T04VL00206
Total Completed Inspections - 2
Date Description Inspector Results Comments
10/23/2006 EXCAVATION/LAYOUT REBAR & ZON CTREVILL Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) WRAP ALL PLUMBING EXPOSED TO CONCRETE
2) ?" CLEARANCE SOIL TO REBAR
04/20/2007 PLUMBING - ROUGH, SOIL ROHAVER Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) MUST UNCOVER ALL PLUMBING PIPING
2) REBAR TO BE MINIMUM 3" AWAY FROM PIPING
3) REBAR TO BE MINIMUM 3" AWAY FROM DIRT
4) MINIMUM 15" OVERLAP REBAR
5) REMOVE RUST FOR REBAR-FOOTINGS TO BE DUG STRAIGHT DOWN FROM FORMS
6) AT PRESLAB INSPECTION ALL PLUMBING TO BE WRAPPED IN CONTACT WITH CONCRETE

Documents

File Name Document Type  
None DOCUMENTS VIEW