Permit: T04PL02212
Permit Details
Apply Date:
12/15/2004
Applicant:
BOWEN MARK DAVID JR & HILDA JT/RS
Description:
REPAIR:GAS LINE
Outstanding Activity Conditions
Permit Number - T04PL02212
Permit Status: Final
Permit Description: REPAIR:GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/15/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04PL02212
Permit Description: REPAIR:GAS LINE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :10PSI AIR TEST SHALL BE ON ENTIRE GAS SYSTEM AT TIME OF INSPECTION WITH NO PRESSURE DROP FOR 15 MINUTES PRIME AND TAPE ALL FITTING & TOOL MARK ON UNDERGROUND PIPING PIPE PRIME & 10 MIL TAPE UNDERGROUND PIPING SHALL BE ON FIRM BEDDING WHOLE UNIONS ARE NECESSARY RIGHT AND LEFT NIPPLES & COUPLINGS SHALL BE USED OR PROVIDE AGA OR CSA GAS VALVE THEN UNION AT BUILDING SERVICE ENTRANCE PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES SECURE ALL PIPING PROPERLY PROVIDE 6" CLEARANCE FROM SINGLE WALL VENT OR 1" FROM DOUBLE WALL VENT AND CORRECT TRANSITION TO LARGER DUCT AT WATER HEATER WITH APPROVED CAP PROVIDE BONDING OF BUILDING GAS PIPING |
| 12/30/2004 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
| 01/13/2005 | PERMIT FINALED | JWEATHER | Approved |