Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
6707 E COOPER ST
Address NEW:
6707 E COOPER ST
Apply Date:
12/15/2004
Applicant:
BOWEN MARK DAVID JR & HILDA JT/RS
Description:
REPAIR:GAS LINE

Outstanding Activity Conditions

Permit Number - T04PL02212
Permit Status: Final
Permit Description: REPAIR:GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
12/15/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04PL02212
Permit Description: REPAIR:GAS LINE
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/30/2004 PLUMBING - FINAL RRICH Approved IVRS - Inspection :10PSI AIR TEST SHALL BE ON ENTIRE GAS SYSTEM AT TIME OF INSPECTION WITH NO PRESSURE DROP FOR 15 MINUTES
PRIME AND TAPE ALL FITTING & TOOL MARK ON UNDERGROUND PIPING PIPE PRIME & 10 MIL TAPE
UNDERGROUND PIPING SHALL BE ON FIRM BEDDING
WHOLE UNIONS ARE NECESSARY RIGHT AND LEFT NIPPLES & COUPLINGS SHALL BE USED OR PROVIDE AGA OR CSA GAS VALVE THEN UNION AT BUILDING SERVICE ENTRANCE
PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES
SECURE ALL PIPING PROPERLY
PROVIDE 6" CLEARANCE FROM SINGLE WALL VENT OR 1" FROM DOUBLE WALL VENT AND CORRECT TRANSITION TO LARGER DUCT AT WATER HEATER WITH APPROVED CAP
PROVIDE BONDING OF BUILDING GAS PIPING
12/30/2004 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
01/13/2005 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW