Permit: T04PL02188
Permit Details
Apply Date:
12/13/2004
Applicant:
MICHAEL HARVEY
Description:
REPAIR:GAS LINE & WATER HEATER
Permit Reviews
Permit Number - T04PL02188
Permit Status: Final
Permit Description: REPAIR:GAS LINE & WATER HEATER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/13/2004 | PLUMBING | 12/15/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04PL02188
Permit Status: Final
Permit Description: REPAIR:GAS LINE & WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/13/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04PL02188
Permit Description: REPAIR:GAS LINE & WATER HEATER
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2004 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :*/14 PSI AIT TEST NEW 1" SCOTCH COAT FROM METER UNDERGROUND TO EXISTING BUILDING SERVICE ENTRANCE TO WATER HEATER & FURNACE ONLY OK. 1)RIDGID PIPE THRU FURNACE APPLIANCE HOUSING 2)WATER HEATER TEMPERATURE & PRESSURE RELIEF DEVICE TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH APPROVED INSTALLATION 3)CORRECT VENT AT WATER HEATER DRAFT HOOD. 4)PROVIDE BONDING OF BUILDING GAS PIPING |
| 12/22/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 12/22/2004 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
| 01/11/2005 | PERMIT FINALED | JWEATHER | Approved |