Permit: T04PL02188

Parcel: 134071760


Addresses:

8402 E KENT PL

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/07/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
12/22/2004 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*/14 PSI AIT TEST NEW 1" SCOTCH COAT FROM METER UNDERGROUND TO EXISTING BUILDING SERVICE ENTRANCE TO WATER HEATER & FURNACE ONLY OK. 1)RIDGID PIPE THRU FURNACE APPLIANCE HOUSING 2)WATER HEATER TEMPERATURE & PRESSURE RELIEF DEVICE TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH APPROVED INSTALLATION 3)CORRECT VENT AT WATER HEATER DRAFT HOOD. 4)PROVIDE BONDING OF BUILDING GAS PIPING