Permit: T04PL02176
Permit Details
Apply Date:
12/09/2004
Applicant:
RANGEL RAMON
Description:
new gas line from meter to home
Contractors:
- SENOR ROOTER L L C *C
Outstanding Activity Conditions
Permit Number - T04PL02176
Permit Status: Final
Permit Description: new gas line from meter to home
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/09/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04PL02176
Permit Description: new gas line from meter to home
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/13/2004 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 14 PSI AIR TEST NOW 3/4 PE UNDERGROUND TO BUILDING SERVICE ENTRANCE TO WATER HEATER, FURNACE, DRYER & STOVE OK 3090 CORRECTION MADE GAS CARD AT METER |
| 12/13/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 12/13/2004 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :*/1)PROVIDE BONDING OF BUILDING GAS PIPING 2)PROVIDE 30" HORIZONTAL SCOTCH COAT PIPING AND SCOTCH COAT PIPING VERTICAL IN UNDERGROUND AT TRANSITION RISER OR APPROVED TRANSITION RISER 3)WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLE & COUPLING TO BE USED. 4)T&P DRAIN TO TERMINATE WITH 90 DEGREE DOWN 5)PROVIDE RIDGID PIPE PENETRATION THRU FURNACE APPLIANCE HOUSEING 6)VENT FROM FURNACE WHEN WITHIN 10' OF COOLER TO BE 2' ABOVE TOP OF COOLER INTAKE |
| 05/03/2005 | PERMIT FINALED | LJACKSON | Approved |