Permit: T04PL02176

Parcel: 134110040


Addresses:

7931 E ELI PL

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/13/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/1)PROVIDE BONDING OF BUILDING GAS PIPING 2)PROVIDE 30" HORIZONTAL SCOTCH COAT PIPING AND SCOTCH COAT PIPING VERTICAL IN UNDERGROUND AT TRANSITION RISER OR APPROVED TRANSITION RISER 3)WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLE & COUPLING TO BE USED. 4)T&P DRAIN TO TERMINATE WITH 90 DEGREE DOWN 5)PROVIDE RIDGID PIPE PENETRATION THRU FURNACE APPLIANCE HOUSEING 6)VENT FROM FURNACE WHEN WITHIN 10' OF COOLER TO BE 2' ABOVE TOP OF COOLER INTAKE
12/13/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :* 14 PSI AIR TEST NOW 3/4 PE UNDERGROUND TO BUILDING SERVICE ENTRANCE TO WATER HEATER, FURNACE, DRYER & STOVE OK 3090 CORRECTION MADE GAS CARD AT METER