Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
8500 E LOUISE DR
Address NEW:
8500 E LOUISE DR
Apply Date:
08/06/2004
Applicant:
RUBEN VALENTE
Description:
REPLACE:GASLINE

Permit Reviews

Permit Number - T04PL01404
Permit Status: Expired
Permit Description: REPLACE:GASLINE
Start Date Submittal Complete Date Status  
08/06/2004 PLUMBING 08/06/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04PL01404
Permit Status: Expired
Permit Description: REPLACE:GASLINE
Total Outstanding Activity Conditions - 1
Date Name
08/06/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T04PL01404
Permite Description: REPLACE:GASLINE
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
08/24/2004 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*/NOT READY
1) PROVIDE BONDING OF BUILDING GAS PIPING
2) SCOTCH COAT PIPING MUST EXTEND 6" ABOVE FINISH GRADE MINIUMUM AT METER AND ALL TOOL MARKS SHALL BE PRIMED & WRAPED WITH 10 MIL TAPE.
3) CHANGES IN DIRECTION SHALL BE MADE WITH APPROVED FITTINGS.
4) PROVIDE RIDGID NIPPLE THRU FURANCE APPLIANCE HOUSING
5)GAS PIPING CANNOT BLOCK WATER HEATER SERVICE SPACE
6) WATER HEATER TEMPORATURE & PRESSURE RELIEF TO GRAVITY DRAW TO PAYLIGHT?
7) WATER HEATER TEMPURATURE & RELIEF TO BE SUBMERGED MINIMUM 4" INTO WATER HEATER TANK
THIS MAY NOT BE A COMPLETE LIST
08/24/2004 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW