Permit: T04PL00994
Permit Details
Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
2708 E CROSBY VISTA
Address NEW:
2708 E CROSBY VISTA
Apply Date:
06/08/2004
Applicant:
NORTHERN PIPELINE CONSTRUCTION*C
Description:
REPLACE:GAS LINE (APA)
Contractors:
- NORTHERN PIPELINE CONSTRUCTION*C
Outstanding Activity Conditions
Permit Number - T04PL00994
Permit Status: Closed
Permit Description: REPLACE:GAS LINE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/08/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T04PL00994
Permite Description: REPLACE:GAS LINE (APA)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2004 | PLUMBING - GAS PRESSURE TEST | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 06/09/2004 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :*/ 1) PROVIDE BONDING OF BLD GAS PIPING. 2) PLEASE LEAVE YOUR LEFT/RIGHT NIPPLE AND COUPLING AT BLD FOR SERVICE TIE-IN OR PROVIDE AGA OR CSA APPROVED GAS VALVE THEN UNION FOR YOUR SERVICE TIE-IN. 3) PROVIDE APPROVED VENT CAP ON WTR HTR, 4) YOUR CHOICE FOR METER LOCATION WITH GAS PIPING RUNNING UNDER ELECTRICAL SERVICE EQUIPMENT VIOLATES DEDICATED SPACE FOR ELECTRICAL EQUIPMENT. THIS PIPING CANNOT RUN THRU THIS AREA. 5) IT APPEARS NORTHERN PIPELINE WILL BE DOING SEVERAL BLDS IN THIS AREA. PLEASE HAVE YOUR SUPERVISOR CONTACT ME SO WE CAN MEET THE REQUIREMENTS OF THE CODES INVOLVED. |