Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/09/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) PROVIDE BONDING OF BLD GAS PIPING. 2) PLEASE LEAVE YOUR LEFT/RIGHT NIPPLE AND COUPLING AT BLD FOR SERVICE TIE-IN OR PROVIDE AGA OR CSA APPROVED GAS VALVE THEN UNION FOR YOUR SERVICE TIE-IN. 3) PROVIDE APPROVED VENT CAP ON WTR HTR, 4) YOUR CHOICE FOR METER LOCATION WITH GAS PIPING RUNNING UNDER ELECTRICAL SERVICE EQUIPMENT VIOLATES DEDICATED SPACE FOR ELECTRICAL EQUIPMENT. THIS PIPING CANNOT RUN THRU THIS AREA. 5) IT APPEARS NORTHERN PIPELINE WILL BE DOING SEVERAL BLDS IN THIS AREA. PLEASE HAVE YOUR SUPERVISOR CONTACT ME SO WE CAN MEET THE REQUIREMENTS OF THE CODES INVOLVED. |