Permit: T04PL00528
Permit Details
Apply Date:
03/18/2004
Applicant:
RAM PLUMBING,*C
Description:
REPAIR:GAS LINE (APA)
Contractors:
- RAM PLUMBING,*C
Outstanding Activity Conditions
Permit Number - T04PL00528
Permit Status: Expired
Permit Description: REPAIR:GAS LINE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/18/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04PL00528
Permite Description: REPAIR:GAS LINE (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/19/2004 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999*/ 1) REMOVE THE THREAD PROTECTOR YOU INSTALLED AT THE MAKE UP NIPPLE AND COUPLING AND USE AN APPROVED COUPLING. REMOVE THE EXISTING UNION AT EAST END OF PIPE AND USE A REVERSE THREAD COUPLING AND NIPPLE 2) IF YOU ARE NOT GOING TO CONNECT THE OTHER FURNACE ON THIS GAS LINE, REMOVE THE TEE THAT IS SUPPLYING THE ABANDONED UNIT. OTHERWISE THE 1" GAS PIPE IS NOT ADEQUATE FOR BOTH UNITS. PLEASE PROVIDE SIZING, IT IS NOT ADEQUATE FOR BOTH UNITS. PLEASE PROVIDE SIZING PLAN 3) SYSTEM IS NOT HOLDING PRESSURE. MAKE NECESSARY REPAIRS AND RETEST SYSTEM. NOTE: ALL COUPLINGS ON EXISTING PIPE ARE THREAD PROTECTORS AND MAY LEAK |