Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
116 S KOLB RD
Address NEW:
116 S KOLB RD
Apply Date:
03/18/2004
Applicant:
RAM PLUMBING,*C
Description:
REPAIR:GAS LINE (APA)
Contractors:
  • RAM PLUMBING,*C

Outstanding Activity Conditions

Permit Number - T04PL00528
Permit Status: Expired
Permit Description: REPAIR:GAS LINE (APA)
Total Outstanding Activity Conditions - 1
Date Name
03/18/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T04PL00528
Permite Description: REPAIR:GAS LINE (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/19/2004 PLUMBING - FINAL N/A Denied IVRS - Inspection 0999*/ 1) REMOVE THE THREAD PROTECTOR YOU INSTALLED AT THE MAKE UP NIPPLE AND COUPLING AND USE AN APPROVED COUPLING. REMOVE THE EXISTING UNION AT EAST END OF PIPE AND USE A REVERSE THREAD COUPLING AND NIPPLE 2) IF YOU ARE NOT GOING TO CONNECT THE OTHER FURNACE ON THIS GAS LINE, REMOVE THE TEE THAT IS SUPPLYING THE ABANDONED UNIT. OTHERWISE THE 1" GAS PIPE IS NOT ADEQUATE FOR BOTH UNITS. PLEASE PROVIDE SIZING, IT IS NOT ADEQUATE FOR BOTH UNITS. PLEASE PROVIDE SIZING PLAN 3) SYSTEM IS NOT HOLDING PRESSURE. MAKE NECESSARY REPAIRS AND RETEST SYSTEM. NOTE: ALL COUPLINGS ON EXISTING PIPE ARE THREAD PROTECTORS AND MAY LEAK

Documents

File Name Document Type  
None DOCUMENTS VIEW