Permit: T04ME00493
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
2938 N RIO VERDE DR
Address NEW:
2938 N RIO VERDE DR
Apply Date:
07/16/2004
Applicant:
D AND H AIR CONDITIONING CO,*C
Description:
INSTALL:GAS PACK (APA)
Contractors:
- D AND H AIR CONDITIONING CO,*C
Outstanding Activity Conditions
Permit Number - T04ME00493
Permit Status: Final
Permit Description: INSTALL:GAS PACK (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/16/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04ME00493
Permit Description: INSTALL:GAS PACK (APA)
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2004 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection : See detailed listing on site.| 999*/1)#8 WIRE NOT ADEQUATE FOR 60 AMP CIRCUIT FROM DISCONNECT TO A/C UNIT. PROVIDE A SCREW ON THE COVER PLATE INSIDE DISCONNECT. 2)GAS SHUT OFF VALVE MUST BE NSTALLED BEFORE THE FLEX CONNECTOR. SUPPORT GAS LINE AT ELBOWS. 3)CONDENSATE CANNOT TERMINATE INTO A SEWER VENT. IF TERMINATING TO THE GROUND, DIRECT THE WATER AWAY FROM THE FOUNDATION. RECALL FOR INSPECTION |
| 01/12/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
| 01/13/2005 | PERMIT FINALED | JKOZUCH | Approved |