Permit: T04EL02318
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
3039 E HAWTHORNE ST
Address NEW:
3039 E HAWTHORNE ST
Apply Date:
11/19/2004
Applicant:
ENERGY SOURCE ELECTRIC INC *C
Description:
UPGRADE:ELECTRIC 100-200 AMP (APA)
Contractors:
- ENERGY SOURCE ELECTRIC INC *C
Outstanding Activity Conditions
Permit Number - T04EL02318
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC 100-200 AMP (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/19/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04EL02318
Permite Description: UPGRADE:ELECTRIC 100-200 AMP (APA)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2004 | ELECTRIC - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* OK TO CLEAR CABLE DROP ONLY NBR. |
| 11/29/2004 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : Install 2 ground rods 6 feet apart with a continuous grounding electrode conn THE GROUNDING SYSTEM MUST CONSIST OF ALL OF THE FOLLOWING: 1. 2-5/8'' X 8' GROUND RODS SET 6' APART IN THE AREA NEAR THE SERVICE ENTRANCE. 2. THE COLD WTR. PIPING OF THE INTERIOR OF THE HOUSE. 3. THE GAS PIPING ALSO HOUSE SIDE. LEAVE MESSAGE ON SITE INDICATING WHERE COLD WATER & GAS PIPE BONDS ARE LOCATED. THESE ITEMS ( ALL ) MUST BE ACCESSIBLE AND READILY INSPECTABLE ( W/O USING LADDER ETC) THANKS |
Completed Inspections
Permit Status: Expired
Permit Number: T04EL02318
Permit Description: UPGRADE:ELECTRIC 100-200 AMP (APA)
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2004 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection :* |
| 11/30/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | CEC |