Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address NEW:
2550 E WATER ST #01
Apply Date:
07/13/2004
Applicant:
ALL RESIDENTIAL AND COMMERCIAL ELECTRIC LLC *T
Description:
UPGRADE:ELECTRIC TO 200AMP (APA)
Contractors:
  • ALL RESIDENTIAL AND COMMERCIAL ELECTRIC LLC *T

Outstanding Activity Conditions

Permit Number - T04EL01454
Permit Status: Closed
Permit Description: UPGRADE:ELECTRIC TO 200AMP (APA)
Total Outstanding Activity Conditions - 1
Date Name
07/13/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T04EL01454
Permite Description: UPGRADE:ELECTRIC TO 200AMP (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
07/14/2004 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 30 AMP 2 POLE 6E BREAKER NOT LISTED FOR THIS PANEL 2) CLOSED NIPPLES (BOTTOM) TO HAVE 2 LOCKNUTS ONE OUTSIDE AS WELL AS INSIDE PANEL 3) 1/2" LB TOP RH SIDE TO HAVE CLOSED NIPPLE WITH LOCK NUTS INSIDE AND OUTSIDE AND LOCK NUT OUTSIDE TO BE SEALING TYPE BECAUSE ENTRY ABOVE BUS 4) REMOVE 1" SHEET METAL SCREWS ON DEADFRONT COVER THESE CAN HARM WIRES INSIDE-USE CORRECT ONES 6) SECURE 3/4" CONDUIT RIGHT SIDE WITHIN 12" OF ENTRY 7) CLOSE UP J-BOXES ON SOUTH EXTERIOR WALL OF HOUSE AND SUPPORT 1/2" EMT NEAR GRADE 8) CLOSE J-BOX ABOVE WATER HEATER 9) WILL NEED LADDER TO ROOF TO CHECK WATER AND GAS BOND

Documents

File Name Document Type  
None DOCUMENTS VIEW