Permit: T04EL01090
Permit Details
Apply Date:
05/24/2004
Applicant:
CORRECT CONNECTIONS INC *C
Description:
UPGRADE:ELECTRIC (APA)
Contractors:
- CORRECT CONNECTIONS INC *C
Outstanding Activity Conditions
Permit Number - T04EL01090
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/24/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04EL01090
Permite Description: UPGRADE:ELECTRIC (APA)
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/18/2004 | ELECTRIC - UNDERGROUND | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 06/18/2004 | ELECTRIC - INTERMEDIATE | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 06/18/2004 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ARIEL CONDUCTORS TO BE INSTALLED PER 230-24 AND 110-14 - 8' OFF OF ROOF AND USE APPROVED SPLICE INSULATION. 2) GROUNDING ELECTRODE SYSTEM NEEDED AT 2ND STRUCTURE DISCONNECT. 3) DRYWALL SCREWS NOT ALLOWED FOR MOUNTING HARDWARE. 4) PLEASE VERIFY WTR AND GAS BONDS. 5) NM CABLE NOT ALLOWED IN A COMPLETE RACEWAY SYSTEM. 6) #8 THHN AMPACITY ONLY 50 AMPS. #8 NM CABLE AMPACITY ONLY 40 AMPS. 7) PLEASE VERIFY A/C PERMIT FOR NEW SERVICE. |