Permit: T04EL00941
Permit Details
Status:
Withdrwn
Type:
SINGLE FAMILY OTHER
Address:
607 N DESERT AV #02
Address NEW:
607 N DESERT AV #02
Apply Date:
05/06/2004
Applicant:
SEAN BLOOM
Description:
RECONNECT:ELECTRIC:GARAGE
Outstanding Activity Conditions
Permit Number - T04EL00941
Permit Status: Withdrwn
Permit Description: RECONNECT:ELECTRIC:GARAGE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/06/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Withdrwn
Permit Number: T04EL00941
Permite Description: RECONNECT:ELECTRIC:GARAGE
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/07/2004 | ELECTRIC - RECONNECT | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 05/07/2004 | ELECTRIC - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1)FILL UNUSED OPENINGS IN PANELS 2)CORRECTLY TERMINATE GROUNDING EQUIPMENT CONDUCTOR AND IDENTIFY AS PER CODE. 3) WE HAVE MULTIPLE TERMINATIONS AT MAIN PANEL. 4) SEPARATE GOUNDS AND NEUTRALS AT SUB PANEL 250-24. 5) INSTALL CONDUCTORS IN FULL RACEWAY SYSTEM 6) TIGHTEN LOOSE FITTINGS. 7) correctly install junction box for cooler and use approved boxes for cooler connections. 8) install splice in junction box. |