Permit: T04EL00482
Permit Details
Apply Date:
03/09/2004
Applicant:
MARTINEZ JORGE E & MARIA G JT/RS
Description:
RECONNECT:ELECTRIC
Outstanding Activity Conditions
Permit Number - T04EL00482
Permit Status: Closed
Permit Description: RECONNECT:ELECTRIC
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/09/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T04EL00482
Permite Description: RECONNECT:ELECTRIC
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2004 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection 0920* |
| 03/10/2004 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0245*/ 1) VERIFY PERMIT AND INSP RECORDS FOR RECENT ELECTRICAL WORK ON PREMISES, THERE ARE TWO SERVICES, NONE IDENTIFIED, MULTIPLE VIOLATIONS ON SITE. POWER ON AT SERVICE EAST BLDG. NO PERMIT PULLED. SERVICE AT WEST END IN VIOLATION OF DEDICATED WORKING SPACE. DOUBLE LUGGING NOT ALLOWED AT MAIN BREAKER, EXPOSED WIRING THRU-OUT, OPEN BOXES, BROKEN OR UNSUPPORTED CONDUIT/WIRING, COVERS MISSING ON BOXES AND SUB-PANEL OUTSIDE BY CAR LIFT NOT OUTDOOR RATED. L-11 LICENSED CONTR. TO MAKE ALL REPAIRS. PERMITS REQUIRED FOR SERVICE UPGRADE AND 1 HOUR GENERAL REPAIR. |