Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address NEW:
2142 E HANCOCK VISTA
Apply Date:
02/10/2004
Applicant:
MESA RUDY
Description:
RECONNECT:ELECTRIC:SFR

Outstanding Activity Conditions

Permit Number - T04EL00268
Permit Status: Closed
Permit Description: RECONNECT:ELECTRIC:SFR
Total Outstanding Activity Conditions - 1
Date Name
02/10/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T04EL00268
Permite Description: RECONNECT:ELECTRIC:SFR
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
02/11/2004 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection 0999*/ 1) SERVICE NEEDS AN ADDRESS [PERMANENT - NO MARKER]. 2) DRYER OUTLET NEEDS A NUETRAL AND 30 AMP SP BREAKER GE. 3) SERVICE NEEDS 2 GROUND RODS. 4) TERMINALS ON BREAKER WITH 2 WIRES NEEDS SCREW ONLY 1 WIRE CAN BE ON TERMINAL. 5) OVERHEAD RISER NEEDS A SUPPORT BELOW ROOF. 6) TERMINATE WASHER CIRCUIT TO 20A GE BREAKER. 7) RECEPTACLES BY SINK TO BE GFI. 8) BATH RECEPTACLE TO BE GFI. 9) LIVING ROOM FIXTURE MISSING. 10) SMOKE DETECTORS IN BEDROOMS.

Documents

File Name Document Type  
None DOCUMENTS VIEW