Permit: T04CM05056
Permit Details
Status:
Final
Type:
DUPLEX NEW
Address:
2541 N CROW CREEK LN #01
Address NEW:
2541 N CROW CREEK LN #01
Apply Date:
11/17/2004
Applicant:
KIPPES CONSTRUCTION L L C
Description:
DUPLEX TD#15-88-95
Contractors:
- KIPPES CONSTRUCTION L L C
Permit Reviews
Permit Number - T04CM05056
Permit Status: Final
Permit Description: DUPLEX TD#15-88-95
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/17/2004 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/17/2004 | COMPLETED |
| 11/17/2004 | RESIDENTIAL BLDG/ZONING/NPPO | 11/23/2004 | COMPLETED |
| 11/30/2004 | RESUBMITTAL | 12/06/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM05056
Permit Status: Final
Permit Description: DUPLEX TD#15-88-95
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/17/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04CM05056
Permit Description: DUPLEX TD#15-88-95
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/15/2004 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :*/1)PAHD 22'S ARE MISSING 2)LIVE END OF TENDONS MAY NOT BE DEFLECTED BY SOIL OUTSIDE OF EXCAVATIONS 3)TENDONS IN SLAB ON GRADE MUST BE FLAT PROFILE (EXCEPT @TURN DOWN REV PLAN) 4)RELOCATE TENDONS UP TO 6" T0 AVOID SLAB PENETRATIONS 5)HAVE SPECIAL INSP REPORT @ SITE WITH PLANS PLEASE. 6)OK TO PLACE CONCRETE WHEN SPECIAL INSPECTOR CONFIRMS REPAIRS |
| 12/15/2004 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
| 12/15/2004 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :* |
| 12/16/2004 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection :*/UNDERGROUND ROUGH OK & WRAP OK. PLEACE NOTE SITE SEWER BACKFILLED 2/OUT INSP STEVE LONG 791-5550 |
| 01/14/2005 | PLUMBING - SEWER HCS CONNECT | JSTANLEY | Approved | IVRS - Inspection :* |
| 02/15/2005 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | IVRS - Inspection :*APPROVED |
| 03/22/2005 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection :* APPROVED |
| 04/12/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* OK FOR SHEET ROCK |
| 04/15/2005 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :*OK ROUGH |
| 04/15/2005 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection :* |
| 04/15/2005 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection :* |
| 04/19/2005 | FRAMING | HLEYVA | Approved | IVRS - Inspection :* |
| 05/23/2005 | SHEET ROCK NAILING | BSTEVENS | Approved | IVRS - Inspection :* |
| 05/23/2005 | U VALUE FOR WINDOW | BSTEVENS | Approved | IVRS - Inspection :* |
| 06/01/2005 | STUCCO MESH | BSTEVENS | Approved | IVRS - Inspection :* |
| 07/06/2005 | ELECTRIC - CABLE DROP | RSUBA | Approved | IVRS - Inspection :* |
| 08/22/2005 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* |
| 09/22/2005 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection :* 1) OK TEMP POWER FOR TEST ON UNITS 1 AND 2 |
| 09/23/2005 | TEP CLEARANCE - AM | JWEATHER | Approved | OK ECO FOR UNITS 1 AND 2 PER HOLLANDER |
| 10/06/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :**OK FOR FINAL |
| 10/06/2005 | PLUMBING - FINAL | TRINIVJR | Approved | |
| 10/07/2005 | PLUMBING - GAS PRESS TEST FNL | TRINIVJR | Approved | IVRS - Inspection :*PLBG FINAL IS OK OK FOR C OF O NOTE: MECHANICAL INSPECTOR WILL ISSUE THE GAS CLEARANCE CARD FOR UNIT #2 |
| 10/10/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 10/17/2005 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 02/07/2006 | PERMIT FINALED | JWEATHER | Approved |