Permit: T04CM04516
Permit Details
Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
650 W CALLE MEDINA
Address NEW:
650 W CALLE MEDINA
Apply Date:
10/08/2004
Applicant:
HEYMANN STEPHEN J & MARISA JT/RS
Description:
CONVERT:CARPORT INTO STORAGE/UTILITY ROOM
Outstanding Activity Conditions
Permit Number - T04CM04516
Permit Status: Final
Permit Description: CONVERT:CARPORT INTO STORAGE/UTILITY ROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/08/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04CM04516
Permit Description: CONVERT:CARPORT INTO STORAGE/UTILITY ROOM
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/03/2004 | FRAMING | JRIVA | Approved | IVRS - Inspection :*/ 1) WATER HEATER "B" VENT REQUIRES 1" CLEARANCE TO COMBUSTIBLE MATERIAL 2) ALL ELECTRICAL OUTLETS ARE UNDERGROUNDED. REMOVE ALL COVERS AND DEVICES FOR INSPECTION OF WIRING ALL 120 VOLT CIRCUITS MUST BE 2 WIRE CROSS GROUND 3) PROVIDE 100 SQUARE INCHES COMBUSTION AIR WITHIN 1' OF CEILING AND 100 SQUARE INCHES COMBUSTION AIR WITHIN 12" OF FLOOR FOR GAS WATER HEATER 4) SECURE GAS LINE SO NO MOTION EXISTS 5) WATER HEATER T & P LINE CANNOT HAVE CORRIGATED TUBING 6) DRYER MUST BE ON A 4 WIRE CIRCUIT, 2 HOT 1 GROUND AND 1 NEUTRAL WITH 4 WIRE OUTLET AND PIG TALE 7) INCORRECT METAL BOXES USED OUTSIDE 8) SUPPORT PLASTIC CONDUIT AT 4' ON CENTER 9) WASHER DRAIN MUST BE 2" WITH A "P" TRAP |
| 12/03/2004 | ELECTRIC - FINAL | JRIVA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/03/2004 | BUILDING - FINAL | JRIVA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/03/2004 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/03/2004 | SHEET ROCK NAILING | JRIVA | Approved | IVRS - Inspection :* |
| 12/03/2004 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection :* |
| 06/02/2005 | PERMIT FINALED | JWEATHER | Approved |