Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address NEW:
650 W CALLE MEDINA
Apply Date:
10/08/2004
Applicant:
HEYMANN STEPHEN J & MARISA JT/RS
Description:
CONVERT:CARPORT INTO STORAGE/UTILITY ROOM

Outstanding Activity Conditions

Permit Number - T04CM04516
Permit Status: Final
Permit Description: CONVERT:CARPORT INTO STORAGE/UTILITY ROOM
Total Outstanding Activity Conditions - 1
Date Name
10/08/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM04516
Permit Description: CONVERT:CARPORT INTO STORAGE/UTILITY ROOM
Total Completed Inspections - 7
Date Description Inspector Results Comments
12/03/2004 FRAMING JRIVA Approved IVRS - Inspection :*/ 1) WATER HEATER "B" VENT REQUIRES 1" CLEARANCE TO COMBUSTIBLE MATERIAL
2) ALL ELECTRICAL OUTLETS ARE UNDERGROUNDED. REMOVE ALL COVERS AND DEVICES FOR INSPECTION OF WIRING ALL 120 VOLT CIRCUITS MUST BE 2 WIRE CROSS GROUND
3) PROVIDE 100 SQUARE INCHES COMBUSTION AIR WITHIN 1' OF CEILING AND 100 SQUARE INCHES COMBUSTION AIR WITHIN 12" OF FLOOR FOR GAS WATER HEATER
4) SECURE GAS LINE SO NO MOTION EXISTS
5) WATER HEATER T & P LINE CANNOT HAVE CORRIGATED TUBING
6) DRYER MUST BE ON A 4 WIRE CIRCUIT, 2 HOT 1 GROUND AND 1 NEUTRAL WITH 4 WIRE OUTLET AND PIG TALE
7) INCORRECT METAL BOXES USED OUTSIDE
8) SUPPORT PLASTIC CONDUIT AT 4' ON CENTER
9) WASHER DRAIN MUST BE 2" WITH A "P" TRAP
12/03/2004 ELECTRIC - FINAL JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/03/2004 BUILDING - FINAL JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/03/2004 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/03/2004 SHEET ROCK NAILING JRIVA Approved IVRS - Inspection :*
12/03/2004 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection :*
06/02/2005 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW