Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/28/2004 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 10/05/2004 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM04335
Permit Description: SFR TD#15-18-28
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/18/2004 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* |
10/21/2004 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* |
10/26/2004 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* |
11/01/2004 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection :* |
11/01/2004 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :* |
11/04/2004 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
11/04/2004 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* |
12/20/2004 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
12/20/2004 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection :* |
12/21/2004 | ELECTRIC - CABLE DROP | RSUBA | Approved | IVRS - Inspection :* |
12/21/2004 | ELECTRIC - TEMPORARY SERVICE | RSUBA | Approved | IVRS - Inspection :* |
12/22/2004 | TEP CLEARANCE - AM | TACHONG | Approved | SENT TO TEP AM |
01/11/2005 | FRAMING | LHANLY | Approved | IVRS - Inspection :*APPROVED |
01/11/2005 | ELECTRIC - INTERMEDIATE | RSUBA | Approved | IVRS - Inspection :*APPROVED |
01/26/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* IK FOR SHEET ROCK |
01/26/2005 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF OK H20 PIPING WATER TEST OK |
01/26/2005 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 27 PSI AIR TEST FROM METER TO STOVE & DRYER ONLY OK |
02/07/2005 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
02/10/2005 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :*AP |
02/17/2005 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* |
04/04/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* OK FOR FINAL |
04/04/2005 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* BUILDING INSPECTOR TO OBTAIN BACKFLOW CERTIFICATION |
04/04/2005 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
04/06/2005 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* GAS CARD LEFT AT SITE STUCCO MESH APPROVED 2/10/05 STUCCO CERT SIGNED 1/18/05 |
04/06/2005 | ELECTRIC - FINAL | LHANLY | Approved | IVRS - Inspection :* |
04/07/2005 | PERMIT FINALED | JWEATHER | Approved |