Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T04CM04335

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
11/04/2004 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
11/03/2004 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)IMPROPER REPAIR OF TENDON SHEATHING - YOU NEED TO FOLLOW P.T.I. GUIDELINES FOR TENDON REPAIR. 1)VOIDS (TENDON SHEATH MISSING AROUND ENTIRE CIRCUMFERENCE OF CABLE) REQUIRES REPLACEMENT SHEATHING. 2)SPLITS AND TEARS MAY BE TAPED
11/01/2004 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*/MAX EXPOSED CABLE @ LINE END TO BE 3" PER PLAN OR BETTER YET 1" PER P.T.I.