Permit: T04CM04213
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
2524 E KLEINDALE RD
Address NEW:
2524 E KLEINDALE RD
Apply Date:
09/17/2004
Applicant:
THE MURPY STUDIO
Description:
ADDITION:GAME ROOM:GUEST ROOM
Permit Reviews
Permit Number - T04CM04213
Permit Status: Expired
Permit Description: ADDITION:GAME ROOM:GUEST ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/04/2005 | RESUBMITTAL | 03/09/2005 | COMPLETED |
| 09/17/2004 | PLANS OK TO SUBMIT - RES | 12/16/2004 | COMPLETED |
| 12/16/2004 | RESIDENTIAL BLDG/ZONING/ENGINE | 01/21/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM04213
Permit Status: Expired
Permit Description: ADDITION:GAME ROOM:GUEST ROOM
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 09/17/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 09/26/2005 | FINAL ELEVATION CERTIFICATE REQUIRED: AN ORIGINAL FINAL ELEVATION CERTIFICATE SEALED BY A REGISTERED LAND SURVEYOR IS REQ'D. MAIL ELEVATION CERTIFICATE TO: CITY OF TUCSON, PLANNING & DEVELOPMENT SERVICES DEPT, ATTN: LOREN MAKUS, P.O. BOX 27210, TUCSON, AZ 85726-7210 OR DELIVER IT TO THE 1ST FL NORTH SIDE OF 201 N. STONE AVE. THIS CONDITION APPLIES TO ALL FINAL INSPECTIONS (1090, 2090, 3090, 4090) AND SHOULD NOT BE SCHEDULED UNTIL THE ELEVATION CERTIFICATE AND THE CONDITION HAVE BEEN APPROVED. LOREN'S IS 837-4927. |
| 02/09/2005 | The proposed building is impacted by the regulatory floodplain. The floodplain 100-year water surface elevation (WSE) just upstream of the or proposed building is 2386.35 feet. The building must be elevated above the floodplain 100-year WSE. This can be achieved by either building up the building pad to the 100-year WSE or higher, or elevating the building by any other acceptable method such as stem walls, piers, etc, depending on what the drainage report, the engineer or the owner is proposing. The building lowest finish floor, utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), or an open utility platform that provides utility services for the structure on this property, under this permit shall, be placed at a minimum of 2387.35 (1 foot above 2386.35) feet above see level, NGVD 1929 as certified by a Registered Land Surveyor. This Certification (Elevation Certificate) is required and must be completed and returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 N. Stone Avenue. This Certification must be completed and returned prior to the final inspection, occupancy of the structure, or issuance of Certificate of Occupancy. |
Completed Inspections
Permit Status: Expired
Permit Number: T04CM04213
Permit Description: ADDITION:GAME ROOM:GUEST ROOM
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/28/2005 | ROOF NAILING | EDURAZO | Approved | IVRS - Inspection :* |
| 06/30/2005 | FRAMING | DQUINN | Approved | IVRS - Inspection :* |
| 06/30/2005 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | IVRS - Inspection :* |
| 06/30/2005 | BUILDING PRE-SLAB | DQUINN | Approved | IVRS - Inspection :* |
| 06/30/2005 | STEM WALL/RETAINING WALL | DQUINN | Approved | IVRS - Inspection :* |
| 06/30/2005 | EXCAVATION/LAYOUT REBAR & ZON | DQUINN | Approved | IVRS - Inspection :* |
| 07/22/2005 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 07/22/2005 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 08/04/2005 | ELECTRIC - UNDERGROUND | BSTEVENS | Approved | IVRS - Inspection :* |
| 08/05/2005 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
| 08/10/2005 | ELECTRIC - SERVICE UPGRADE | RCAMACHO | Approved | IVRS - Inspection :* |
| 08/12/2005 | TEP CLEARANCE - AM | FGREER | Approved | INC CLEARED BY CAMACHO |
| 08/31/2005 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 08/31/2005 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 08/31/2005 | BUILDING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 02/27/2006 | PERMIT FINALED | LJACKSON | Approved |