Permit Reviews

Permit Number - T04CM04066
Permit Status: C of o
Permit Description: NEW:PHYSICAL EDUCATION BUILDING
Start Date Submittal Complete Date Status  
01/12/2005 RESUBMITTAL 01/31/2005 COMPLETED Review Details
04/27/2005 REVISION 05/18/2005 COMPLETED Review Details
09/08/2004 PLANS OK TO SUBMIT - 3RD PARTY 09/08/2004 COMPLETED Review Details
09/08/2004 3RD PARTY REVIEW-COMMERCIAL 10/18/2004 COMPLETED Review Details
10/18/2004 POST 3RD PARTY REVIEW 10/27/2004 COMPLETED Review Details
12/16/2004 RESUBMITTAL 12/29/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM04066
Permit Status: C of o
Permit Description: NEW:PHYSICAL EDUCATION BUILDING
Total Outstanding Activity Conditions - 1
Date Name
09/08/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM04066
Permit Description: NEW:PHYSICAL EDUCATION BUILDING
Total Completed Inspections - 31
Date Description Inspector Results Comments
02/01/2005 EXCAVATION/LAYOUT REBAR & ZON HLEYVA Approved IVRS - Inspection :* APPROVED
02/01/2005 ELECTRIC - UFER DSANTACR Approved APPROVED
02/08/2005 STEM WALL/RETAINING WALL AMATHIES Approved IVRS - Inspection :*APPROVED
02/22/2005 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) NOTE: BLDG. DRAIN IS STUBBED OUT @ TWO WAY C. O LOCATION ONLY. 3) AIR PRESSURE TEST FOR DOMESTIC WATER UNDER SLAB IS OK AND IS STUBBED OUT OF BLDG 2'-0" ONLY 4) OK TO BACKFILL TRENCH.
03/08/2005 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection :*
03/23/2005 REINFORCED MASONRY PRE-GROUT AMATHIES Approved IVRS - Inspection :* APPROVED
04/06/2005 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection :*
05/04/2005 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection :* OK TO COVER HARD LIDS
05/04/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
05/10/2005 ROOF NAILING AMATHIES Approved IVRS - Inspection :*
05/16/2005 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection :*
05/16/2005 FRAMING AMATHIES Approved IVRS - Inspection :*
05/25/2005 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
05/31/2005 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection :*
1) ABOVE CEILING IS OK
2) FINAL CONNECTION TO METER AND BACKFLOW PREVENTERS ARE OK
05/31/2005 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection :*
06/02/2005 BUILDING ABOVE CEILING AMATHIES Approved IVRS - Inspection :*
06/03/2005 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :* / 1) CORRECTIONS MADE OK. REVISED PLAN ON SITE. STAGNANT WTR CONNECTION CORRECTED. 2) ENGINEERING ON SITE SEWER IN ORDER.
06/20/2005 OUTDOOR LIGHTING FINAL DSANTACR Approved IVRS - Inspection :*
07/11/2005 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection :* CLOSET FLANGES ARE OK
07/29/2005 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
08/01/2005 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
08/10/2005 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection :*
1) PLUMBING FINAL OK
2) OK FOR C OF O
08/11/2005 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved IVRS - Inspection :*
1) GAS PRESSURE TEST IS OK
2) FINAL CONNECTIONS TO GAS PACKS OK
08/11/2005 PLUMBING - GAS PRESS TEST FNL TRINIVJR Approved IVRS - Inspection :*
08/26/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
1) SMOKE ALARM RELOCATED TO CORRECT POSITION
09/16/2005 FIRE - FINAL LTHOMAS Approved
09/16/2005 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
09/19/2005 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
11/30/2006 ENGINEERING - FINAL MFLICK Approved Tetra Tech re-analysis of the drainage conditions and wall stability is acceptable and shows less than 100 cfs affecting the gymnasium. No elevation certificate is required. TUSD to submit letter acknowledging that COT wall now provides flood protection, but may not in the future.
12/05/2006 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*
12/06/2006 PERMIT FINALED BFLORES Approved