Permit: T04CM03666
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
7268 E CHELSIE KAYE LN
Address NEW:
7268 E CHELSIE KAYE LN
Apply Date:
08/09/2004
Applicant:
DESERT AMERICAN BUILDERS CORP ,C
Description:
SFR TD#15-89-16
Contractors:
- DESERT AMERICAN BUILDERS CORP ,C
Permit Reviews
Permit Number - T04CM03666
Permit Status: C of o
Permit Description: SFR TD#15-89-16
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/09/2004 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 08/09/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM03666
Permit Status: C of o
Permit Description: SFR TD#15-89-16
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/09/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM03666
Permit Description: SFR TD#15-89-16
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2004 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :*/PARTIAL-WATER TEST WASTE & VENT UNDERGROUND ONLY (PARTIAL) PENDING VERIFICATION FROM ENGNIEER FOR MANHOLE DEING HIGHER THAN FLOOD ROM OF ALL FIXTURES IN BCD, SO BACKWATER INSTALLATION IS REQUIRED> 1) BACKWATER VALVES TO BE EXTENDED TO GRADE IF REQUIRD 2) PROVIDE CERTIFICATE OF CONFORMANCE FROM PIMA COUNTY ADEQ FOR SITE SEWER INSTALLATION AND VERIFICATION OF INSPECTION OF SITE SEWER. 3) 03055-SEWER HCS CONNECTION TO BE CALLED IN AND CORRECT TRANSITION GLUE OR APPROVED COUPLING SHALL BE USED AT THIS LOCATION. |
| 09/01/2004 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* |
| 09/01/2004 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection :* |
| 09/01/2004 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
| 09/24/2004 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection :* |
| 11/01/2004 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection :* |
| 11/08/2004 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :*/REPAIR DAMAGED FLEX DUCT TO EXHAUST FAN & SUPPORT AT ROOF PENETRATION. STRAP UP FLEX DUCT. OK FOR SHEET ROCK |
| 11/08/2004 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
| 11/08/2004 | FRAMING | LHANLY | Approved | IVRS - Inspection :* |
| 11/12/2004 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection :* |
| 11/12/2004 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
| 11/17/2004 | STUCCO MESH | HLEYVA | Approved | IVRS - Inspection :* |
| 11/30/2004 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :*/CORRECTION MADE |
| 12/14/2004 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :*APPROVED. |
| 01/04/2005 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :*APPROVED |
| 03/25/2005 | ELECTRIC - TEMPORARY SERVICE | RSUBA | Approved | IVRS - Inspection :* 1) OK TO CLEAR |
| 03/28/2005 | TEP CLEARANCE - AM | HLEYVA | Approved | TEMP POWER CLEARED BY SUBA |
| 04/13/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :*OK FOR FINAL. LEE RAY WILL CHECK CIRCUIT BREAKER FOR A/C |
| 04/13/2005 | ELECTRIC - UFER | RSUBA | Approved | |
| 04/13/2005 | ELECTRIC - CABLE DROP | RSUBA | Approved | |
| 04/13/2005 | ELECTRIC - FINAL | RSUBA | Approved | IVRS - Inspection :* INSTALL FURRING-FLASH RINGS AT RECEPTACLES FOR DISPOSAL & HOOD WHERE GREATER THAN 1/4" GAP TO WOOD |
| 04/15/2005 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
| 04/15/2005 | PLUMBING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
| 04/15/2005 | PLUMBING - SEWER HCS CONNECT | LHANLY | Approved | IVRS - Inspection :* |
| 04/18/2005 | PERMIT FINALED | JKOZUCH | Approved |