Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
COMMERCIAL NEW
Address NEW:
8130 S HOUGHTON RD
Apply Date:
06/07/2004
Applicant:
KURT FRIMODIG
Description:
NEW SHELL RETAIL 90' x 75' SHELL BUILDING, MASONRY W/ TRUSS ROOF
Architects:
  • KUBICEK, ROBERT W ARCHITECTS & ASSOCIATES
Contractors:
  • RIO WEST DEVELOPMENT AND CONSTRU

Permit Reviews

Permit Number - T04CM02546
Permit Status: Final
Permit Description: NEW SHELL RETAIL 90' x 75' SHELL BUILDING, MASONRY W/ TRUSS ROOF
Start Date Submittal Complete Date Status  
02/22/2005 3RD PARTY REVIEW-REVISION/OTHER 04/21/2005 COMPLETED Review Details
06/07/2004 PLANS OK TO SUBMIT - 3RD PARTY 06/07/2004 COMPLETED Review Details
06/07/2004 3RD PARTY REVIEW-COMMERCIAL 09/29/2004 COMPLETED Review Details
09/29/2004 POST 3RD PARTY REVIEW 10/15/2004 COMPLETED Review Details
10/15/2004 RESUBMITTAL 12/01/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM02546
Permit Status: Final
Permit Description: NEW SHELL RETAIL 90' x 75' SHELL BUILDING, MASONRY W/ TRUSS ROOF
Total Outstanding Activity Conditions - 1
Date Name
06/07/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM02546
Permit Description: NEW SHELL RETAIL 90' x 75' SHELL BUILDING, MASONRY W/ TRUSS ROOF
Total Completed Inspections - 35
Date Description Inspector Results Comments
12/13/2004 ELECTRIC - UFER RSUBA Approved IVRS - Inspection :*
12/17/2004 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
12/21/2004 REINFORCED MASONRY PRE-GROUT LHANLY Approved IVRS - Inspection :*
12/29/2004 ELECTRIC - CONSTRUCTION POWER RSUBA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) FINISH TEMP SERVICE
03/11/2005 PLUMBING - ROUGH, SOIL JSTANLEY Approved IVRS - Inspection :* TEST OK ON UNDERGROUND SOIL PLEASE WRAP WASTE LINE IN SLAB
05/04/2005 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
05/04/2005 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
06/30/2005 ROOF NAILING LHANLY Approved IVRS - Inspection :*
07/22/2005 PLUMBING - ROOF DRAINS LHANLY Approved IVRS - Inspection :*
08/01/2005 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection :*
08/01/2005 FRAMING LHANLY Approved IVRS - Inspection :*
08/10/2005 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
09/14/2005 ELECTRIC - UNDERGROUND RSUBA Approved IVRS - Inspection :
See detailed listing on site.| 999*
09/29/2005 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :* R VALUES ON DUCT ARE OK AS PER PLANS
10/04/2005 BUILDING - FINAL AMATHIES Approved IVRS - Inspection :*
11/07/2005 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection :*
11/07/2005 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*PLEASE RECALL FOR INSPECTOR SUBA
11/08/2005 TEP CLEARANCE - AM JKOZUCH Approved H.P # 4 ECO
12/21/2005 OUTDOOR LIGHTING FINAL RSUBA Approved IVRS - Inspection :*
12/21/2005 ELECTRIC - CABLE DROP RSUBA Approved IVRS - Inspection :*
12/21/2005 ELECTRIC - ABOVE CEILING RSUBA Approved IVRS - Inspection :*
12/21/2005 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection :*
12/21/2005 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection :*
12/30/2005 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :* HP -1 # 8 WIRE NOT ADEQUATE FOR 60 AMP CIRCUIT
HP 2,3 DISCONNECTS OVERFUSED . 25 AMP IS MAX CONNECT CONDENSATE DRAINS.
PERMANENTLY IDENTIFY UNITS & HEAT STRIPS.
PROVIDE COIL GUARD FOR HP -1
12/30/2005 PLUMBING - FINAL LHANLY Approved IVRS - Inspection :*
1) NEED PLAN SHOWING 100 AND 106 DELETED AND BACKFLOW CERTIFICATE
12/30/2005 FIRE - FINAL LTHOMAS Approved
12/30/2005 FIRE SPKLR - FINAL LTHOMAS Approved
12/30/2005 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
08/25/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
08/28/2006 PERMIT FINALED BFLORES Approved
08/28/2006 PLUMBING - SEWER HCS CONNECT RRICH Approved
08/28/2006 PLUMBING - YARD WTR LINE/TEST RRICH Approved
08/28/2006 PLUMBING - ABOVE CEILING RRICH Approved
08/28/2006 PLUMBING - INTERMEDIATE RRICH Approved
08/28/2006 ELECTRIC - INTERMEDIATE RSUBA Approved