Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
COMMERCIAL NEW
Address NEW:
3675 E BRITANNIA DR
Apply Date:
04/21/2004
Applicant:
N/A
Description:
WAREHOUSE:NEW SHELL 225'4" x 361'4" CONCRETE TILT-UP BUILDING W/ INTERIOR STEEL STRUCTURE, STEEL ROOF JOISTS AND STEEL ROOF DECKING, ONE-HOUR FIRE-RATED WALL SEPARATING SES ROOM AND WAREHOUSE REVISION FOR SHOP DRAWINGS : SHOP DRAWINGS APPROVED FOR:1. TILT-UP WALLS,2. STRUCTURAL STEEL,3. METAL ROOF DECKING,4. METAL ROOF JOISTS ,5. STEEL LADDER ,6. ROOF LATCH. REVISION FOR LOADING DOCK AND CANOPY : (10/26/04) PROVIDE SHOP DRAWINGS FOR CANOPY STEEL , METAL DECKING , HANDRAILS AND GUARDRAILS SHOP DRAWINGS SUBMITTED FOR LOADING DOCK GUARDRAIL, DOCK HANDRAIL, GUARDRAIL, CANOPY FRAMING, COLUMNS, CANOPY BEAMS, (12/9/04) (12/30/04) LOADING DOCK SHOP DRAWINGS FOR : 1. CANOPY METAL DECKING, 2. CANOPY STEEL FRAMING, 3.GUARDS ,4. HANDRAILS.
Contractors:
  • OPUS SOUTHWEST CONSTRUCTION CORP

Permit Reviews

Permit Number - T04CM01811
Permit Status: Final
Permit Description: WAREHOUSE:NEW SHELL 225'4" x 361'4" CONCRETE TILT-UP BUILDING W/ INTERIOR STEEL STRUCTURE, STEEL ROOF JOISTS AND STEEL ROOF DECKING, ONE-HOUR FIRE-RATED WALL SEPARATING SES ROOM AND WAREHOUSE REVISION FOR SHOP DRAWINGS : SHOP DRAWINGS APPROVED FOR:1. TILT-UP WALLS,2. STRUCTURAL STEEL,3. METAL ROOF DECKING,4. METAL ROOF JOISTS ,5. STEEL LADDER ,6. ROOF LATCH. REVISION FOR LOADING DOCK AND CANOPY : (10/26/04) PROVIDE SHOP DRAWINGS FOR CANOPY STEEL , METAL DECKING , HANDRAILS AND GUARDRAILS SHOP DRAWINGS SUBMITTED FOR LOADING DOCK GUARDRAIL, DOCK HANDRAIL, GUARDRAIL, CANOPY FRAMING, COLUMNS, CANOPY BEAMS, (12/9/04) (12/30/04) LOADING DOCK SHOP DRAWINGS FOR : 1. CANOPY METAL DECKING, 2. CANOPY STEEL FRAMING, 3.GUARDS ,4. HANDRAILS.
Start Date Submittal Complete Date Status  
04/21/2004 PLANS OK TO SUBMIT - COMM 04/23/2004 COMPLETED Review Details
04/21/2004 PLANS OK TO SUBMIT - SITE 04/21/2004 COMPLETED Review Details
04/21/2004 SITE 05/26/2004 COMPLETED Review Details
04/23/2004 COMMERCIAL NEW 05/26/2004 COMPLETED Review Details
06/15/2004 RESUBMITTAL 06/24/2004 COMPLETED Review Details
06/15/2004 RESUBMITTAL - SITE ALL 07/09/2004 COMPLETED Review Details
06/24/2004 RESUBMITTAL 07/09/2004 COMPLETED Review Details
07/15/2004 RESUBMITTAL 07/23/2004 COMPLETED Review Details
08/13/2004 REVISION 09/10/2004 COMPLETED Review Details
09/10/2004 REVISION - 2ND 10/15/2004 COMPLETED Review Details
10/22/2004 RESUBMITTAL 11/03/2004 COMPLETED Review Details
11/10/2004 RESUBMITTAL - SITE 12/30/2004 COMPLETED Review Details
11/10/2004 RESUBMITTAL 12/30/2004 COMPLETED Review Details
12/09/2004 REVISION 12/13/2004 COMPLETED Review Details
12/30/2004 REVISION 01/04/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM01811
Permit Status: Final
Permit Description: WAREHOUSE:NEW SHELL 225'4" x 361'4" CONCRETE TILT-UP BUILDING W/ INTERIOR STEEL STRUCTURE, STEEL ROOF JOISTS AND STEEL ROOF DECKING, ONE-HOUR FIRE-RATED WALL SEPARATING SES ROOM AND WAREHOUSE REVISION FOR SHOP DRAWINGS : SHOP DRAWINGS APPROVED FOR:1. TILT-UP WALLS,2. STRUCTURAL STEEL,3. METAL ROOF DECKING,4. METAL ROOF JOISTS ,5. STEEL LADDER ,6. ROOF LATCH. REVISION FOR LOADING DOCK AND CANOPY : (10/26/04) PROVIDE SHOP DRAWINGS FOR CANOPY STEEL , METAL DECKING , HANDRAILS AND GUARDRAILS SHOP DRAWINGS SUBMITTED FOR LOADING DOCK GUARDRAIL, DOCK HANDRAIL, GUARDRAIL, CANOPY FRAMING, COLUMNS, CANOPY BEAMS, (12/9/04) (12/30/04) LOADING DOCK SHOP DRAWINGS FOR : 1. CANOPY METAL DECKING, 2. CANOPY STEEL FRAMING, 3.GUARDS ,4. HANDRAILS.
Total Outstanding Activity Conditions - 1
Date Name
04/21/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM01811
Permit Description: WAREHOUSE:NEW SHELL 225'4" x 361'4" CONCRETE TILT-UP BUILDING W/ INTERIOR STEEL STRUCTURE, STEEL ROOF JOISTS AND STEEL ROOF DECKING, ONE-HOUR FIRE-RATED WALL SEPARATING SES ROOM AND WAREHOUSE REVISION FOR SHOP DRAWINGS : SHOP DRAWINGS APPROVED FOR:1. TILT-UP WALLS,2. STRUCTURAL STEEL,3. METAL ROOF DECKING,4. METAL ROOF JOISTS ,5. STEEL LADDER ,6. ROOF LATCH. REVISION FOR LOADING DOCK AND CANOPY : (10/26/04) PROVIDE SHOP DRAWINGS FOR CANOPY STEEL , METAL DECKING , HANDRAILS AND GUARDRAILS SHOP DRAWINGS SUBMITTED FOR LOADING DOCK GUARDRAIL, DOCK HANDRAIL, GUARDRAIL, CANOPY FRAMING, COLUMNS, CANOPY BEAMS, (12/9/04) (12/30/04) LOADING DOCK SHOP DRAWINGS FOR : 1. CANOPY METAL DECKING, 2. CANOPY STEEL FRAMING, 3.GUARDS ,4. HANDRAILS.
Total Completed Inspections - 29
Date Description Inspector Results Comments
07/29/2004 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection :*
08/18/2004 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection :*/APPROVED
1)SOIL WATER TEST IS OK
2)OK TO BACKFILL TRENCH
08/24/2004 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
08/30/2004 ELECTRIC - TEMPORARY POLE RMAJUTA Approved APPROVED OK TO CLEAR
08/31/2004 TEP CLEARANCE - AM JKOZUCH Approved TEMP POWER POLE FOR CONSTRUCTION ONLY
09/20/2004 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection :*
10/18/2004 ROOF NAILING AMATHIES Approved IVRS - Inspection :*
10/20/2004 STEM WALL/RETAINING WALL AMATHIES Approved IVRS - Inspection :*
10/22/2004 FRAMING AMATHIES Approved IVRS - Inspection :*
11/16/2004 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection :*/1)PIT FOR BACK WATER VALVE IS OK 2)YARD WATER LINE OK BACKFLOW PREVENTER OK
11/16/2004 PLUMBING - PROGRESS TRINIVJR Approved IVRS - Inspection :*
11/16/2004 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved IVRS - Inspection :*
11/16/2004 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection :*
11/24/2004 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection :*
11/24/2004 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection :*
11/24/2004 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection :*
12/01/2004 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
12/07/2004 ELECTRIC - TEMP POWER FOR TEST DSANTACR Approved
12/21/2004 BUILDING - FINAL AMATHIES Approved IVRS - Inspection :*
1) OK TEMP C OF O
12/22/2004 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
12/22/2004 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
12/22/2004 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection :*
12/23/2004 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
12/27/2004 FIRE SPKLR - FINAL LTHOMAS Approved Approval for shell building only.
12/30/2004 FIRE - FINAL LTHOMAS Approved OKAY TEMP C OF O
01/07/2005 STUCCO MESH AMATHIES Approved IVRS - Inspection :*
01/10/2005 NPPO - FINAL ACONNOR Approved
01/10/2005 LANDSCAPE - FINAL ACONNOR Approved
01/27/2005 PERMIT FINALED TACHONG Approved