Permit: T04CM01761
Permit Details
Apply Date:
04/16/2004
Applicant:
N/A
Description:
BANK:NEW
Architects:
- MORROW, KEVIN THOMAS
Contractors:
- OLLANIK CONSTRUCTION *C
Permit Reviews
Permit Number - T04CM01761
Permit Status: C of o
Permit Description: BANK:NEW
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/16/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 04/30/2004 | COMPLETED |
| 04/16/2004 | PLANS OK TO SUBMIT - SITE | 04/16/2004 | COMPLETED |
| 04/19/2004 | SITE | 06/11/2004 | COMPLETED |
| 07/01/2004 | 3RD PARTY REVIEW-COMMERCIAL | 07/01/2004 | COMPLETED |
| 07/01/2004 | POST 3RD PARTY REVIEW | 07/12/2004 | COMPLETED |
| 07/07/2002 | RESUBMITTAL - SITE ALL | 07/13/2004 | COMPLETED |
| 07/22/2004 | RESUBMITTAL - SITE | 12/15/2004 | COMPLETED |
| 07/22/2004 | RESUBMITTAL | 12/15/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM01761
Permit Status: C of o
Permit Description: BANK:NEW
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/16/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM01761
Permit Description: BANK:NEW
Total Completed Inspections - 36
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
| 03/14/2005 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | |
| 04/26/2005 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection :* 1) YARD WATER LINE FROM METER OT BLDG SERVICE IS OK. 2) BACKWATER INSTALLATION IS OK. 3) OK TO BACKFILL TRENCH. |
| 04/26/2005 | PLUMBING - BACK WATER VALVE | TRINIVJR | Approved | IVRS - Inspection :* |
| 04/27/2005 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 04/28/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 05/02/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :* 1) SOIL WATER TEST ON DWV SYSTEM IS OK. 2) OVERHEAD WATER DISTRIBUTION IS OK 3) NOTE: SHALL SEE CLOSET FLANGES WHEN INSTALLED PRIOR TO SETTING WATER CLOSETS. |
| 05/02/2005 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :* |
| 05/10/2005 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* |
| 05/10/2005 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 05/17/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 05/24/2005 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection :* |
| 05/27/2005 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection :* 1) HCS CONNECTION HAS BEEN INSPECTED BY BOB RICH 1/31/05 |
| 06/07/2005 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 06/08/2005 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | OK TO CLEAR TEMP POWER FOR TEST SUBJECT TO BOND POSTING |
| 06/08/2005 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* |
| 06/16/2005 | TEP CLEARANCE - PM | JKOZUCH | Approved | ECO PER GERARDO BONILLAS |
| 06/21/2005 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 07/01/2005 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection :* |
| 07/01/2005 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection :* |
| 07/07/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* 1) PLBG FINAL IS OK. 2) OK FOR C OF O |
| 07/07/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 07/07/2005 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection :* |
| 07/07/2005 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 07/13/2005 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection :* |
| 07/15/2005 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* |
| 07/21/2005 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 07/21/2005 | OUTDOOR LIGHTING FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 07/22/2005 | FIRE - FINAL | CSCHULTZ | Approved | |
| 07/25/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 07/26/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | |
| 07/26/2005 | ENGINEERING - FINAL | MAVERY | Approved | Contractor needs to finish: 1- Clean up of northside of property. (Rake down area northside of block wall.) 2- Paint ballards in trash enclosure. |
| 07/27/2005 | NPPO - FINAL | ACONNOR | Approved | |
| 07/27/2005 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 07/28/2005 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 07/29/2005 | RIGHT OF WAY - FINAL | RLEIGH | Approved | OK FOR RELEASE |