Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
04/05/2004
Applicant:
U S HOME OF ARIZONA *P
Description:
SFR:TD#15-44-70
Contractors:
  • U S HOME OF ARIZONA *P

Permit Reviews

Permit Number - T04CM01562
Permit Status: C of o
Permit Description: SFR:TD#15-44-70
Start Date Submittal Complete Date Status  
04/05/2004 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 04/05/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM01562
Permit Status: C of o
Permit Description: SFR:TD#15-44-70
Total Outstanding Activity Conditions - 1
Date Name
04/05/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T04CM01562
Permit Description: SFR:TD#15-44-70
Total Completed Inspections - 24
Date Description Inspector Results Comments
04/30/2004 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
04/30/2004 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
04/30/2004 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
06/03/2004 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
06/03/2004 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :*/ 1) SHIM UNDER HIP JACKS FRONT BEDROOM 2)NAIL TO ROOF LAST SHEAR PANEL REAR 3) ADD WIND BRACE S. WALL 4) BLOCK UNDER TRIANGLE OSB TURNED WRONG WAY FRONT HIP 5) SHIM RBI TRUSS 6) PLEASE HAVE PT INSP. CHECK CABLE DOG REAR STEM 7) WILL CHECK AT INTERMEDIATE INSP
06/07/2004 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
06/07/2004 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
06/08/2004 TEP CLEARANCE - PM JKOZUCH Approved
06/21/2004 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
06/23/2004 U VALUE FOR WINDOW RFREIDIN Approved IVRS - Inspection :*
06/23/2004 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection :*
06/23/2004 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
06/23/2004 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
06/23/2004 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
06/23/2004 FRAMING RFREIDIN Approved IVRS - Inspection :*
06/25/2004 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
08/04/2004 PERMIT FINALED RFREIDIN Approved
08/04/2004 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
08/04/2004 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
08/04/2004 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
08/04/2004 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*
08/05/2004 ELECTRIC - UFER RFREIDIN Approved
08/05/2004 BUILDING PRE-SLAB RFREIDIN Approved
08/05/2004 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved