Permit Reviews

Permit Number - T04CM00368
Permit Status: Final
Permit Description: SFR:NEW
Start Date Submittal Complete Date Status  
01/28/2004 3RD PARTY REVIEW-RESIDENTIAL 02/17/2004 COMPLETED Review Details
05/24/2004 POST 3RD PARTY REVIEW 06/29/2004 COMPLETED Review Details
08/12/2004 RESUBMITTAL 08/17/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM00368
Permit Status: Final
Permit Description: SFR:NEW
Total Outstanding Activity Conditions - 1
Date Name
01/28/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T04CM00368
Permit Description: SFR:NEW
Total Completed Inspections - 29
Date Description Inspector Results Comments
12/07/2004 PLUMBING - YARD WTR LINE/TEST ROHAVER Approved IVRS - Inspection :*/ 1) H20 AND SEWER OK FROM STREET TO APPROX 200' WEST STUBBED AT LARGE SAGUARO CACTUS APPROX 30' FROM HOUSE PADS
12/07/2004 PLUMBING - SEWER HCS CONNECT ROHAVER Approved IVRS - Inspection :*
12/16/2004 EXCAVATION/LAYOUT REBAR & ZON ROHAVER Approved IVRS - Inspection :*
1) RETAINER FOOTING OK TO POUR AS NOTED BELOW
2) FRONT AND SIDES OK; BACK RETAINING WALL (WEST SIDE) NOT READY
3) THESE WALLS ARE INDEPENDENT OF HOUSE WALLS
09/28/2005 PLUMBING - ROUGH, SOIL ROHAVER Approved IVRS - Inspection :*
11/03/2005 ELECTRIC - UFER ROHAVER Approved IVRS - Inspection :*
12/06/2005 REINFORCED MASONRY PRE-GROUT ROHAVER Approved IVRS - Inspection :*
1) 1ST LIFT (48")
2) 2 MASONRY COLUMN 24" X 24" (FRONT SIDE MAIN ENTRY)
12/14/2005 BUILDING PRE-SLAB EDURAZO Approved IVRS - Inspection :*
12/14/2005 STEM WALL/RETAINING WALL EDURAZO Approved IVRS - Inspection :*
12/21/2005 EXT METAL CLIPS/EXT SHEATHING ROHAVER Approved IVRS - Inspection :*
1) EXTERIOR CLIPS AT LEDGER
2) MAIN HOUSE OK (PORCHES NOT READY)
3) WILL NEED ENGINEER OF RECORD APPROVAL ON PLYWOOD LEDGERS AND PLATES
01/26/2006 ROOF NAILING DQUINN Approved IVRS - Inspection :*
06/14/2006 ELECTRIC - INTERMEDIATE ROHAVER Approved IVRS - Inspection :*
1) FRONT OVERHANGS ELECTRIC LIGHT WIRES OK TO LATHE (EXTERIOR)
11/15/2006 ELECTRIC - CABLE DROP ROHAVER Approved IVRS - Inspection :*
12/27/2006 ELECTRIC - TEMPORARY SERVICE CRUIZ Approved IVRS - Inspection :*
12/28/2006 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER C. RUIZ
02/06/2007 U VALUE FOR WINDOW ROHAVER Approved IVRS - Inspection :*
02/06/2007 STUCCO MESH ROHAVER Approved IVRS - Inspection :*
02/06/2007 PLUMBING - GAS PRESSURE TEST ROHAVER Approved IVRS - Inspection :*
02/06/2007 MECHANICAL - INTERMEDIATE ROHAVER Approved IVRS - Inspection :*
02/06/2007 PLUMBING - INTERMEDIATE ROHAVER Approved IVRS - Inspection :*
02/06/2007 FRAMING ROHAVER Approved IVRS - Inspection :*
02/28/2007 SHEET ROCK NAILING ROHAVER Approved IVRS - Inspection :*
07/16/2007 MECHANICAL - FINAL CRUIZ Approved IVRS - Inspection :*
07/16/2007 PLUMBING - FINAL CRUIZ Approved IVRS - Inspection :*
07/16/2007 PLUMBING - GAS PRESS TEST FNL CRUIZ Approved IVRS - Inspection :*
07/16/2007 FIRE - FINAL LTHOMAS Approved
07/16/2007 FIRE SPKLR - FINAL LTHOMAS Approved
07/18/2007 ELECTRIC - FINAL CRUIZ Approved
07/18/2007 BUILDING - FINAL CRUIZ Approved IVRS - Inspection :*
01/14/2008 PERMIT FINALED LJACKSON Approved