Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM00368
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/06/2007 | FRAMING | Approved | IVRS - Inspection :* | |
01/12/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BANG PLATE OVER CEILING JOIST AT COPPER LINE WEST BED 2) CHECK FIREBLOCKING AT DROP CEILINGS THROUGHOUT 3) COMPLETE FRAMING AT FIREPLACE IN LIVING ROOM 4) BANG PLATES OVER PLUMBING IN M. BATH 5) 1" CLEARANCE TO COMBUSTIBLES AT ALL B-VENTS 6) BOND WATER PIPE 7) VACUUM BREAKERS ON HOSE BIBS 8) MAINTAIN 2" SCREED TO GRADE 9) NO GAS PRESSURE |