Permit: T04BU02149
Permit Details
Apply Date:
08/30/2004
Applicant:
FENECK GROUP INC , THE
Description:
GRADING:CUT 2400 CY FILL 1700 CY
Contractors:
- QUALIFIED MECHANICAL SERVICES INC
Permit Reviews
Permit Number - T04BU02149
Permit Status: Expired
Permit Description: GRADING:CUT 2400 CY FILL 1700 CY
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/30/2004 | PLANS OK TO SUBMIT - GRADING | 08/30/2004 | COMPLETED |
| 08/31/2004 | GRADING | 09/27/2004 | COMPLETED |
| 12/02/2004 | RESUBMITTAL - GRADING ALL | 12/28/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04BU02149
Permit Status: Expired
Permit Description: GRADING:CUT 2400 CY FILL 1700 CY
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/30/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T04BU02149
Permite Description: GRADING:CUT 2400 CY FILL 1700 CY
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2007 | GRADING - INTERMEDIATE | N/A | Correction Required | PRIOR TO APPROVAL FOR FINAL GRADING: 1) PROVIDE A CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD STATING THAT THE RET/DET BASINS AND SURFACE DRAINAGE WAS CONSTRUCTED PER THE APPROVED GRADING PLAN. 2) PROVIDE A STAMPED DRAWING FROM THE ENGINEER OF RECORD SHOWING CHANGES MADE TO THE SOUTH PARKING AREA, BLOCK WALL, AND SURFACE DRAINAGE. 3) COMPLETE STRIPING FROM HC RAMP TO RIGHT-OF-WAY ALONG WEST SIDE OF BLDG. #1. 4) INSTALL HC ACCESS RAMPS ALONG EAST SIDE OF BLDGS #1 AND#2. ENSURE ALL HC RAMPS MEET CURRENT ADA REQUIREMENTS. 5) RET/DET BASIN LOCATED IN THE NW CORNER OF SITE HOLDS WATER LONGER THAN 24 HOURS - REPAIR BASIN TO ENSURE STORM WATER DOES NOT POND FOR LONGER THAN 24 HOURS. 6) CLEAN OUT INLET PIPE TO NW BASIN. 7) REPAIR EROSION OF NORTH SLOPE OF NW BASIN. 8) ENSURE SIDE SLOPES OF DRAINAGE CHANNEL/BASIN ALONG WEST SIDE OF SITE ARE 3:1 OR FLATTER. BASINS THAT ARE 2' DEEP WITH SIDE SLOPES GREATER THAN A 3:1 REQUIRE SAFETY RAILING. |
| 12/27/2007 | GRADING - FINAL | N/A | Correction Required | 1) NEED FINAL GRADING APPROVAL 2) NEED TO COMPLETE TRASH ENCLOSURE ON SE SIDE. 3) NEED CERT LETTER FROM ENGINEER AND APPROVED DRAWING SHOWING CHANGES MADE TO THE ORIGINAL APPROVED GRADING PLAN. 4) NEED TRUNCATED DOMES INSTALLED ON HC RAMPS. 5) BASIN AT NW CORNER OF SITE HOLDS WATER. NEED TO REPAIR EROSION DAMAGE AND CLEAN OUT BOTTOM OF BASIN. |
Completed Inspections
Permit Status: Expired
Permit Number: T04BU02149
Permit Description: GRADING:CUT 2400 CY FILL 1700 CY
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2004 | NPPO PRE PERMIT INSPECTION | JLINVILL | Approved | |
| 12/30/2004 | ENGINEERING PRE-CONSTRUCTION | JSALINE | Approved | STORM WATER PRE-CONSTRUCTION MEETING: CORRECTIONS REQUIRED> 1) INSTALL SILT-FENCING AND STABILIZE CONSTRUCTION ENTRANCE ON MONDAY THE 3RD. 2) POST AZPDES FORM AT THE ENTRANCE OF THE SITE. RE-INSPECT ON TUESDAY THE 4TH. |
| 06/23/2005 | STORMWATER INSTALL OF CONTROLS | MRUSSO | Approved | |
| 11/15/2007 | LANDSCAPE INSPECTION | ACONNOR | Approved | |
| 12/27/2007 | STORMWATER FOLLOW-UP INSP | MRUSSO | Approved | 1) NEED FINAL GRADING APPROVAL 2) NEED TO COMPLETE TRASH ENCLOSURE ON SE SIDE. 3) NEED CERT LETTER FROM ENGINEER AND APPROVED DRAWING SHOWING CHANGES MADE TO THE ORIGINAL APPROVED GRADING PLAN. 4) NEED TRUNCATED DOMES INSTALLED ON HC RAMPS. 5) BASIN AT NW CORNER OF SITE HOLDS WATER. NEED TO REPAIR EROSION DAMAGE AND CLEAN OUT BOTTOM OF BASIN. |
| 01/14/2008 | STORMWATER FINAL INSPECTION | MRUSSO | Approved |